M-system R7L-TS4-R Instruction Manual

Thermocouple input module, 4 points (lonworks)

Advertisement

Quick Links

INSTRUCTION MANUAL
THERMOCOUPLE INPUT MODULE, 4 points
BEFORE USE ....
Thank you for choosing M-System. Before use, please check
contents of the package you received as outlined below.
If you have any problems or questions with the product,
please contact M-System's Sales Office or representatives.
■ PACKAGE INCLUDES:
Thermocouple input module (body + 4 CJC sensors) ........(1)
NeuronID label ....................................................................(2)
■ MODEL NO.
Confirm Model No. marking on the product to be exactly
what you ordered.
■ INSTRUCTION MANUAL
This manual describes necessary points of caution when
you use this product, including installation, connection and
basic maintenance procedures.
LNS Plug-in Software (model: R7LPLG) is usable to set up
Functional Blocks. For detailed information, refer to the
R7PLG Users Manual. The R7LPLG is downloadable at M-
System's web site: http://www.m-system.co.jp
SEN TRONIC
(L
W
)
ON
ORKS
056 222 38 18
mailbox@sentronic.com
AG
MODEL
POINTS OF CAUTION
■ POWER INPUT RATING & OPERATIONAL RANGE
• Locate the power input rating marked on the product and
confirm its operational range as indicated below:
24V AC rating: 24V ±10%, 50/60 Hz, approx. 85mA
24V DC rating: 24V ±10%, approx. 50mA
■ GENERAL PRECAUTIONS
• Before you remove the unit or mount it, turn off the power
supply and input signal for safety.
■ ENVIRONMENT
• Indoor use.
• When heavy dust or metal particles are present in the
air, install the unit inside proper housing with sufficient
ventilation.
• Do not install the unit where it is subjected to continuous
vibration. Do not subject the unit to physical impact.
• Environmental temperature must be within -10 to +55°C
(14 to 131°F) with relative humidity within 30 to 90% RH
in order to ensure adequate life span and operation.
■ WIRING
• Do not install cables close to noise sources (relay drive
cable, high frequency line, etc.).
• Do not bind these cables together with those in which
noises are present. Do not install them in the same duct.
■ AND ....
• The unit is designed to function as soon as power is sup-
plied, however, a warm up for 10 minutes is required for
satisfying complete performance described in the data
sheet.
www.sentronic.com
R7L-TS4
EM-7804-B Rev.8 P. 1 / 19

Advertisement

Table of Contents
loading

Summary of Contents for M-system R7L-TS4-R

  • Page 1 ORKS BEFORE USE ..POINTS OF CAUTION Thank you for choosing M-System. Before use, please check ■ POWER INPUT RATING & OPERATIONAL RANGE contents of the package you received as outlined below. • Locate the power input rating marked on the product and...
  • Page 2: Component Identification

    R7L-TS4 COMPONENT IDENTIFICATION Service SW Reset SW Factory Configuration Port Indicator LED Status Indicator LED SVCE TX/RX ONLINE 10 11 12 13 15 16 17 18 , Power Supply ORKS Terminals Input Terminals ■ STATUS INDICATOR LED ■ POWER SUPPLY, L TERMINAL ASSIGNMENT ORKS COLOR...
  • Page 3: Terminal Connections

    R7L-TS4 TERMINAL CONNECTIONS Connect the unit as in the diagram below. ■ EXTERNAL DIMENSIONS unit: mm (inch) 115 (4.53) 17 (.66) 54 (2.13) DIN RAIL 35mm wide 10 11 12 13 15 16 17 18 30 (1.18) [5 (.20)] 6 (.24) 6 (.24) 7–M3 SCREW 18–M3 SCREW...
  • Page 4: Communication Cable Connections

    R7L-TS4 COMMUNICATION CABLE CONNECTIONS ■ HOST PC CONNECTION HOST PC R 7L R 7L ORKS ORKS ORKS Terminator WIRING INSTRUCTIONS ■ SCREW TERMINAL Torque: 0.5 N·m ■ SOLDERLESS TERMINAL Refer to the drawing below for recommended ring tongue terminal size. Spade tongue type is also applicable. Applicable wire size: 0.25 to 1.65 mm (AWG 22 to 16) Recommended manufacturer: Japan Solderless Terminal...
  • Page 5: Functional Blocks

    Device Interface File (XIF) is used to define a L device when programmed on LonMaker. ORKS For this module, the following file is used: R7L-TS4v110.XIF The XIF files are downloadable at M-System’s web site: http://www.m-system.co.jp FUNCTIONAL BLOCKS ■ NodeObject NodeObject (Object ID : 0) Network Variables...
  • Page 6 R7L-TS4 • Configuration Properties TYPE CONFIGURATION NETWORK { Range } EXPLANATIONS PROPERTY VARIABLE { Default } Bit 0, Bit 1: Setting the extension module (Power supply must be reset when this configuration property is changed.) 0,0 : Without extension module {SNVT_state} 1,0 : Discrete input (fb and other settings assigned to the 9th {0 or 1}...
  • Page 7 R7L-TS4 ■ FUNCTIONAL BLOCK: fbCNT[0...7] fbCNT[0...7] (Object ID : 17...24) Network Variables nviCNTIn nvoCNTOut nv 36 nv 52 ...nv 43 SNVT_switch SNVT_count_32 ...nv 59 SNVT_count_f nviCNTCtrl nv 44 ...nv 51 SNVT_switch Configuration Properties fbCNT[ ] : SCPTdirection Set operating mode nviCNTIn : SCPTinvrtOut Set count logic (ON or OFF)
  • Page 8 R7L-TS4 • Configuration Properties TYPE CONFIGURATION NETWORK { Range } EXPLANATIONS PROPERTY VARIABLE { Default } Bit 0 through 4: Counted object 0,0,0,0,0 : nviCNTIn 1,0,0,0,0 : ExX0 0,1,0,0,0 : ExX1 1,1,0,0,0 : ExX2 0,0,1,0,0 : ExX3 1,0,1,0,0 : ExX4 0,1,1,0,0 : ExX5 1,1,1,0,0 : ExX6 0,0,0,1,0 : ExX7...
  • Page 9 R7L-TS4 ■ FUNCTIONAL BLOCK: fbTS[0...3] fbTS [0...3] (Object ID : 25...28) Network Variables nvoTSVal nv 60 SNVT_temp ...nv 63 SNVT_temp_p nv 64 nvoTSPVal SNVT_lev_percent ...nv 67 Configuration Properties fbTS : SCPTsceneNmbr Set input sensor type nvoTSVal : SCPTnvType Network variable type SCPTminDeltaTemp Deviation temperature to send SCPToffset [ ]...
  • Page 10 R7L-TS4 • Configuration Properties TYPE CONFIGURATION NETWORK { Range } EXPLANATIONS PROPERTY VARIABLE { Default } Input sensor type for Input 0 through 3 0 : K (CA) 1 : E (CRC) 2 : J (IC) 3 : T (CC) 4 : B (RH) 5 : R SCPTsceneNmbr...
  • Page 11 R7L-TS4 ■ FUNCTIONAL BLOCK: fbCV[0...3] fbCV[0...3] (Object ID : 29...32) Network Variables nviCVIn nvoCVOut SNVT_lev_percent SNVT_lev_percent nv 68 nv 72 SNVT_temp SNVT_temp ...nv 71 ...nv 75 SNVT_temp_p SNVT_temp_p SNVT_count_32 SNVT_count_32 Configuration Properties nviCVIn : SCPTnumDigits Set the value source SCPTnvType Network variable type SCPTsetpoint[ ] 0% and 100% setpoints...
  • Page 12 R7L-TS4 • Configuration Properties TYPE CONFIGURATION NETWORK { Range } EXPLANATIONS PROPERTY VARIABLE { Default } Source of the input to nviCVIn 0 : LonMaker bound output network variable 60 : fbTS[0] nvoTSVal {SNVT_count} 61 : fbTS[1] nvoTSVal SCPTnumDigits nviCVIn {0,60...63} 62 : fbTS[2] nvoTSVal 63 : fbTS[3] nvoTSVal...
  • Page 13 R7L-TS4 ■ FUNCTIONAL BLOCK: fbARM[0...3] fbARM[0...3] (Object ID : 33...36) Network Variables nviARMIn nvoARM1 nv 80 SNVT_lev_percent nv 76 SNVT_switch ...nv 83 SNVT_temp ...nv 79 SNVT_temp_p SNVT_count_32 nvoARM2 nv 84 SNVT_switch ...nv 87 nvoARM3 nv 88 SNVT_switch ...nv 91 nvoARM4 nv 92 SNVT_switch ...nv 95...
  • Page 14 R7L-TS4 • Configuration Properties TYPE CONFIGURATION NETWORK { Range } EXPLANATIONS PROPERTY VARIABLE { Default } Source of the input to nviARMIn 0 : LonMaker bound output network variable 60 : fbTS[0] nvoTSVal 61 : fbTS[1] nvoTSVal 62 : fbTS[2] nvoTSVal {SNVT_count} 63 : fbTS[3] nvoTSVal SCPTnumDigits...
  • Page 15 R7L-TS4 TYPE CONFIGURATION NETWORK { Range } EXPLANATIONS PROPERTY VARIABLE { Default } {SNVT_lev_percent} {0.000...163.835} {5.000} {SNVT_temp} {0.0...6279.5} {5.0} SCPToffset nviARMIn Alarm deadband (hysteresis) {SNVT_temp_p} {0.00...327.66} {5.00} {SNVT_count_32} {0...999 999 999} {50} ■ FUNCTIONAL BLOCK: fbLED fbLED (Object ID : 37) Network Variables nviLEDState nv 96...
  • Page 16 R7L-TS4 ■ FUNCTIONAL BLOCK: fbDOEX[0...7] This Functional Block is valid only when the output extension module is specified at NodeObject. fbDOEX[0...7] (Object ID : 1...8) Network Variables nviDOEX1 nv 4 ...nv 11 SNVT_switch nviDOEX2 nv 12 ...nv 19 SNVT_switch Configuration Properties fbDOEX[ ] : SCPTdirection Set operating mode...
  • Page 17 R7L-TS4 ■ FUNCTIONAL BLOCK: fbDOEX[0...7] • Network Properties TYPE NETWORK { Range } EXPLANATIONS VARIABLE { Default } Turns on or off Y0, Y2, Y4, Y6, Y8, YA, YC, YE of the extension module {SNVT_switch} depending upon this input. nviDOEX1 {0.0 0}, {100.0 1}, {Invalid} 100.0 1 : ON {0.0 0}...
  • Page 18 R7L-TS4 ■ FUNCTIONAL BLOCK: fbDIEX[0...7] This Functional Block is valid only when the input extension module is specified at NodeObject. fbDIEX[0...7] (Object ID : 9...16) Network Variables nvoDIEX1 nv 20 ...nv 27 SNVT_switch nvoDIEX2 nv 28 ...nv 35 SNVT_switch Configuration Properties fbDIEX[ ] : SCPTdirection Set operating mode...
  • Page 19 R7L-TS4 ■ FUNCTIONAL BLOCK: fbDIEX[0...7] • Network Variables Normal Mode TYPE NETWORK { Range } EXPLANATIONS VARIABLE { Default } {SNVT_switch} nvoDIEX1 {0.0 0}, {100.0 1}, {Invalid} Outputs X0, X2, X4, X6, X8, XA, XC, XE status of the extension module {0.0 0} {SNVT_switch} nvoDIEX2...

This manual is also suitable for:

R7l-ts4R7 series

Table of Contents