INSTRUCTION MANUAL
DISCRETE INPUT MODULE, 16 points
(Modbus 115.2 kbps)
BEFORE USE ....
Thank you for choosing M-System. Before use, please check
contents of the package you received as outlined below.
If you have any problems or questions with the product,
please contact M-System's Sales Office or representatives.
■ PACKAGE INCLUDES:
Discrete input module ...................................................... (1)
■ MODEL NO.
Confirm that the model number described on the product is
exactly what you ordered.
■ INSTRUCTION MANUAL
This manual describes necessary points of caution when
you use this product, including installation, connection and
basic maintenance procedures.
SEN TRONIC
POINTS OF CAUTION
■ CONFORMITY WITH EU DIRECTIVES
• The actual installation environments such as panel con-
figurations, connected devices and connected wires may
affect the protection level of this unit when it is integrat-
ed in a panel system. The user may have to review the CE
requirements in regard to the whole system and employ
additional protective measures to ensure CE conformity.
■ POWER INPUT RATING & OPERATIONAL RANGE
• Locate the power input rating marked on the product and
confirm its operational range as indicated below:
24V DC rating: 24V ±10%, approx. 40mA
■ GENERAL PRECAUTIONS
• Before you remove the unit or mount it, turn off the power
supply and input signal for safety.
■ ENVIRONMENT
• Indoor use.
• When heavy dust or metal particles are present in the
air, install the unit inside proper housing with sufficient
ventilation.
• Do not install the unit where it is subjected to continuous
vibration. Do not subject the unit to physical impact.
• Environmental temperature must be within -10 to +55°C
(14 to 131°F) with relative humidity within 30 to 90% RH
in order to ensure adequate life span and operation.
■ WIRING
• Do not install cables close to noise sources (relay drive
cable, high frequency line, etc.).
• Do not bind these cables together with those in which
noises are present. Do not install them in the same duct.
■ AND ....
• The unit is designed to function as soon as power is sup-
plied, however, a warm up for 10 minutes is required for
satisfying complete performance described in the data
sheet.
056 222 38 18
mailbox@sentronic.com
AG
R7M-DA16F
R7M-DA16F
MODEL
EM-7803-AW Rev.1 P. 1 / 4
www.sentronic.com

Advertisement

loading
Need help?

Need help?

Do you have a question about the R7 Series and is the answer not in the manual?

Questions and answers

Summary of Contents for M-system R7 Series

  • Page 1 (Modbus 115.2 kbps) BEFORE USE ..POINTS OF CAUTION Thank you for choosing M-System. Before use, please check ■ CONFORMITY WITH EU DIRECTIVES contents of the package you received as outlined below. • The actual installation environments such as panel con-...
  • Page 2 R7M-DA16F COMPONENT IDENTIFICATION SIDE VIEW FRONT VIEW (A) Status Indicator LED 1 2 3 4 5 6 7 8 (B) Node Address Setting Rotary SW 0 1 2 3 4 5 6 7 8 9 A B C D E F (C) Baud Rate Setting Rotary SW CNFG.
  • Page 3 R7M-DA16F EXTERNAL DIMENSIONS UNIT: MM (INCh) 115 (4.53) 17 (.66) 54 (2.13) DIN RAIL 35 mm wide 10 11 12 13 15 16 17 18 30 (1.18) [5 (.20)] 6 (.24) 6 (.24) 7–M3 SCREW 18–M3 SCREW TERMINALS TERMINALS for Modbus, POWER for INPUT CONNECTION DIAGRAM Connect the unit as in the diagram below.
  • Page 4 R7M-DA16F MASTER CONNECTION Host PC Remote Unit Remote Unit TERMINATOR TERMINATOR Tx+/Rx+ Tx–/Rx– Rx– Be sure to connect the terminating resistor included in the product package to the unit at both ends of transmission line. The terminator must be connected across DA and DB. The Host PC can be located other than at the extreme ends of transmission line.

This manual is also suitable for:

R7m-da16fR7m-da16f-r