INSTRUCTION MANUAL
PNP TRANSISTOR OUTPUT EXTENSION MODULE, 16 points
(Ethernet Modbus/TCP)
BEFORE USE ....
Thank you for choosing M-System. Before use, please check
contents of the package you received as outlined below.
If you have any problems or questions with the product,
please contact M-System's Sales Office or representatives.
■ PACKAGE INCLUDES:
Discrete output extension module ................................... (1)
■ MODEL NO.
Confirm that the model number described on the product is
exactly what you ordered.
■ INSTRUCTION MANUAL
This manual describes necessary points of caution when
you use this product, including installation, connection and
basic maintenance procedures.
POINTS OF CAUTION
■ CONFORMITY WITH EU DIRECTIVES
• The actual installation environments such as panel con-
figurations, connected devices and connected wires may
affect the protection level of this unit when it is integrat-
ed in a panel system. The user may have to review the CE
requirements in regard to the whole system and employ
additional protective measures to ensure CE conformity.
■ POWER INPUT RATING & OPERATIONAL RANGE
• Locate the power input rating marked on the product and
confirm its operational range as indicated below:
24V DC rating: 24V ±10%, approx. 20mA
■ GENERAL PRECAUTIONS
• Before you remove the unit or mount it, turn off the power
supply and output signal for safety.
■ ENVIRONMENT
• Indoor use.
• When heavy dust or metal particles are present in the
air, install the unit inside proper housing with sufficient
ventilation.
• Do not install the unit where it is subjected to continuous
vibration. Do not subject the unit to physical impact.
• Environmental temperature must be within -10 to +55°C
(14 to 131°F) with relative humidity within 30 to 90% RH
in order to ensure adequate life span and operation.
■ WIRING
• Do not install cables close to noise sources (relay drive
cable, high frequency line, etc.).
• Do not bind these cables together with those in which
noises are present. Do not install them in the same duct.
■ AND ....
• The unit is designed to function as soon as power is sup-
plied, however, a warm up for 10 minutes is required for
satisfying complete performance described in the data
sheet.
SEN TRONIC
COMPONENT IDENTIFICATION
■ DISCRETE OUTPUT STATUS INDICATOR LED
Discrete output extension modules have LED indicators
showing output signal status.
Contact ON: LED ON
Contact OFF: LED OFF
■ OUTPUT TERMINAL ASSIGNMENT
NO.
1
2
3
4
5
6
7
8
9
056 222 38 18
mailbox@sentronic.com
AG
R7E-EC16B
MODEL
Discrete Output Status Indicator LED
10 11 12 13
1
2
3
4
5
10
11
12
13
14
15
+24V
Y1
Y3
Y5
Y7
1
2
3
4
5
6
0V
Y0
Y2
Y4
Y6
Y8
ID
FUNCTION
NO.
0V
0V
10
+24V
Y0
Output 0
11
Y1
Y2
Output 2
12
Y3
Y4
Output 4
13
Y5
Y6
Output 6
14
Y7
Y8
Output 8
15
Y9
YA
Output 10
16
YB
YC
Output 12
17
YD
YE
Output 14
18
YF
EM-7807-K Rev.2
www.sentronic.com
R7E-EC16B
0
1
2
3
4
5
6
7
8
9
A
B
C
D
E
F
14
15 16 17 18
6
7
8
9
Output Terminals
16
17
18
Y9
YB
YD
YF
7
8
9
YA
YC
YE
ID
FUNCTION
24V DC (common)
Output 1
Output 3
Output 5
Output 7
Output 9
Output 11
Output 13
Output 15
P. 1 / 3