Document Pack Contents S9V2-Vs; Part List - Trane S9V2B040U3VSAE Installation, Operation And Maintenance Manual

Upflow/horizontal and dedicated downflow gas-fired, direct/non-direct vent, 2-stage condensing variable speed furnaces with variable speed draft inducer, upflow, convertible to horizontal right or horizontal left/downflow only
Table of Contents

Advertisement

A A c c c c e e s s s s o o r r i i e e s s

Document Pack Contents S9V2-VS

Qty.
Description
Item
Condensate Drain Tube Assembly
1
1
Inlet Vent
(a)
2
1
3
1
Inlet Vent Gasket
Outlet Vent Assembly
4
1
5
1
Outlet Vent Gasket
6
6
Screws
Condensate Trap Grommet
7
1
Plug – Condensate/Gas
8
1
Plug – Electrical
9
1
Grommet – Condensate/Gas
10
2
Installation, Operation, and Maintenance
11
1
12
1
Owner Guide
Limited Warranty
13
1
2" to 3" Coupling – CPL00938
14
1
(a)
3" inlet vent supplied with S9V2D120U5VS only. 2" inlet vent supplied with all other models.
(b)
Supplied with S9V2D120U5VS only.

Part List

Igniter
Flame Sensor
In-shot Burner(s)
Gas Valve
10
Installation, Operation, and Maintenance
Up ow/Horizontal and Dedicated Down ow
Gas-Fired, Direct/Non-Direct Vent, 2-Stage
Condensing Variable Speed Furnaces with Variable Speed
Draft Inducer
U U p p f fl lo o w w , , C C o o n n v v e e r r t t i i b b l l e e t t o o
H H o o r r i i z z o o n n t t a a l l R R i i g g h h t t o o r r
H H o o r r i i z z o o n n t t a a l l L L e e f f t t
S9V2B040U3VSAE
S9V2B060U3VSAC/D
S9V2B080U4VSAC/D
S9V2C100U4VSAC/D
S9V2D120U5VSAC/D
Failure to follow this Caution could result in property damage or personal injury. 4GXC* and
4MXC* coils installed on upflow furnaces in vertical, horizontal left, or horizontal right
orientations without a factory installed metal drain pan shield must use a MAY*FERCOLKITAA
kit. Coils installed on upflow furnaces must have drain pans that are suitable for 400° F
(205°C) or have a metal drain pan shield. Downflow furnaces do not require a metal drain pan
shield or the use of the MAY*FERCOLKITAA kit.
Only qualified personnel should install and service the equipment. The installation, starting up, and servicing of heating, ventilating, and air-conditioning
equipment can be hazardous and requires specific knowledge and training. Improperly installed, adjusted or altered equipment by an unqualified person
could result in death or serious injury. When working on the equipment, observe all precautions in the literature and on the tags, stickers, and labels that
are attached to the equipment.
December 2022
(b)
Inducer Assembly
Blower Motor
Blower Wheel
IFC (Integrated Furnace Control)
D D o o w w n n f fl lo o w w O O n n l l y y
S9V2B080D4VSAC/D
S9V2C100D4VSAC/D
Note:
Graphics in this document are for representation
only. Actual model may differ in appearance.
CAUTION
!
COIL REQUIREMENT!
S9V2-VS-SVX001-1B-EN