8. Remove 3" plug on right side of unit. To be used for
condensate trap.
9. Install condensate trap grommet.
10. Remove 3" plugs on the left side of the cabinet. To
be used for combustion air inlet.
11. Reuse the two 3" plugs to seal the two 3" default
openings on the top of the furnace.
12. Remove three inducer screws.
13. While the inducer is loose, remove condensate
drain plug from top right location on cold header.
14. Place condensate drain plug onto the cold header
outlet located on the bottom left of the cold header.
15. Rotate the inducer 180 degrees so that the elbow is
pointing towards the left.
82
16. Use the three inducer screws to reattach the
inducer to the cold header. Torque to 30 in.-lbs. Do
not overtighten.