Document Pack Contents; Part List - Trane A952V040BU3SB Installation, Operation And Maintenance Manual

Upflow/horizontal and dedicated downflow gas-fired, direct/non-direct vent, 2-stage condensing variable speed furnaces
Table of Contents

Advertisement

A A c c c c e e s s s s o o r r i i e e s s

Document Pack Contents

Qty.
Description
Item
Condensate Drain Tube Assembly
1
1
Inlet Vent (2"- ADP01586 and 3" -
2
1
ADP01587)
(a)
3
1
Inlet Vent Gasket
Outlet Vent Assembly
4
1
5
1
Outlet Vent Gasket
6
6
Screws
Condensate Trap Grommet
7
1
Plug - Condensate/Gas
8
1
Plug - Electrical
9
1
Grommet - Condensate/Gas
10
2
Installation, Operation, and
11
1
Maintenance
12
1
Owner Guide
Limited Warranty
13
1
2" to 3" Coupling - CPL01544
14
1
15
2
Brand labels
(c)
(a)
3" inlet vent supplied with A952V120DU5S and A952V120DD5S only. 2" inlet vent supplied with all other models.
(b)
Supplied with A952V120DU5S and A952V120DD5S only.
Place appropriate brand label below the warning label on the front panel using stencil marks as guides.
(c)

Part List

Igniter
Flame Sensor
In-shot Burner(s)
Gas Valve
10
Installation, Operation, and Maintenance
Up ow/Horizontal and Dedicated
Down ow Gas-Fired, Direct/Non-Direct Vent,
2-Stage Condensing Variable Speed Furnaces
U U p p f f l l o o w w , , C C o o n n v v e e r r t t i i b b l l e e t t o o
D D o o w w n n f f l l o o w w O O n n l l y y
H H o o r r i i z z o o n n t t a a l l R R i i g g h h t t o o r r
A952V040BD3SB
H H o o r r i i z z o o n n t t a a l l L L e e f f t t
A952V060BD3SB
A952V040BU3SB
A952V080BD4SB
A952V060BU4SB
A952V100CD5SB
A952V080BU4SB
A952V120DD5SB
A952V080CU5SB
A952V100CU5SB
A952V120DU5SB
WARNING
N N o o t t e e : : Graphics in this document are for
FIRE HAZARD!
representation only. Actual model may differ in
Failure to follow this Warning could result in property damage, severe personal
appearance.
injury, or death.
This Warning applies to installations with a ammable refrigeration system.
The furnace must be powered except for service. The furnace shall be installed
and connected according to installation instructions and wiring diagrams that
are provided with the evaporator coil.
!
CAUTION
COIL REQUIREMENT!
Failure to follow this Caution could result in property damage or personal injury. 4GXC* and
4MXC* coils installed on upflow furnaces in vertical, horizontal left, or horizontal right
orientations without a factory installed metal drain pan shield must use a MAY*FERCOLKITAA
kit. Coils installed on upflow furnaces must have drain pans that are suitable for 400° F
(205°C) or have a metal drain pan shield. Downflow furnaces do not require a metal drain pan
shield or the use of the MAY*FERCOLKITAA kit.
S S A A F F E E T T Y Y W W A A R R N N I I N N G G
Only qualified personnel should install and service the equipment. The installation, starting up, and servicing of heating, ventilating, and air-conditioning
equipment can be hazardous and requires specific knowledge and training. Improperly installed, adjusted or altered equipment by an unqualified person
could result in death or serious injury. When working on the equipment, observe all precautions in the literature and on the tags, stickers, and labels that
are attached to the equipment.
A A 9 9 5 5 2 2 V V - - S S V V X X 0 0 0 0 1 1 - - 1 1 B- - E E N N
September 2023
(b)
Inducer Assembly
Blower Motor
Blower Wheel
IFC (Integrated Furnace Control)
Pressure Switch(es)
Main Thermal Limit
Roll-Out Switch(es)
Reverse Air Switch(es)
A952V-SVX001-1B-EN

Advertisement

Table of Contents
loading

Table of Contents