Accessories; Document Pack Contents - Trane S9V2B040U3PSBC Installer's Manual

Upflow/horizontal and dedicated downflow gas-fired, direct/non-direct vent, 2–stage condensing variable speed furnaces
Table of Contents

Advertisement

Accessories

Table 1. Accessories
Model Number
BAYHANG
BAYVENT200B
BAYVENTCN200B
BAYAIR30AVENTA
BAYAIR30CNVENT
BAYREDUCE
BAYLIFTB
BAYLIFTC
BAYLIFTD
BAYBASE205
BAYFLTR206
BAYSF1165AA
(a)
BAYLPSS400*
BAYMFGH200B
BAYCNDTRAP2A
BAYCNDTRAP3A
(a)
Airflow greater than 1600 CFM requires dual returns

Document Pack Contents

Item
Qty.
Description
1
1
Condensate Drain Tube Assembly
2
1
Inlet Vent
(a)
3
1
Inlet Vent Gasket
4
1
Outlet Vent Assembly
5
1
Outlet Vent Gasket
6
6
Screws
7
1
Condensate Trap Grommet
8
1
Plug — Condensate/Gas
9
1
Plug — Electrical
10
2
Grommet — Condensate/Gas
11
1
Installer's Guide
12
1
Service Facts
13
1
Owner Guide
14
1
Limited Warranty
15
1
2" to 3" Coupling — CPL00938
(a)
3" inlet vent supplied with S9V2D120U5PSBC and S9V2D120D5PSBC only. 2" inlet vent supplied with all other models.
(b)
Supplied with S9V2D120U5PSBC and S9V2D120D5PSBC only.
18-CE18D1-1A-EN
Description
Horizontal Hanging Kit
Sidewall Vent Termination Kit
Sidewall Vent Termination Kit (Canada —
CPVC)
Concentric Vent Kit
Concentric Vent Kit (Canada — CPVC)
Reducing Coupling (CPVC)
Dual Return Kit (B size extension)
Dual Return Kit (C size extension)
Dual Return Kit (D size extension)
Downflow Subbase
Filter Access Door Kit (Downflow only)
1" SlimFit Box with MERV 4 Filter
Propane Conversion Kit with Stainless Steel
Burners
Manufactured/Mobile Housing Kit
Inline Condensate Trap Kit used with Special
Venting on 2" Vent Pipe
Inline Condensate Trap Kit used with Special
Venting on 3" Vent Pipe
Installer's Guide
Up ow/Horizontal and Dedicated Down ow
Gas-Fired, Direct/Non-Direct Vent, 2–Stage
Condensing Variable Speed Furnaces
U U p p f f l l o o w w , , C C o o n n v v e e r r t t i i b b l l e e t t o o
D D o o w w n n f f l l o o w w O O n n l l y y
H H o o r r i i z z o o n n t t a a l l R R i i g g h h t t o o r r
S9V2B040D3PSBC
H H o o r r i i z z o o n n t t a a l l L L e e f f t t
S9V2B060D3PSBC
S9V2B040U3PSBC
S9V2B080D4PSBC
S9V2B060U4PSBC
S9V2C100D5PSBC
S9V2B080U4PSBC
S9V2D120D5PSBC
S9V2C080U5PSBC
S9V2C100U5PSBC
S9V2D120U5PSBC
N N o o t t e e : : Graphics in this document are for
!
CAUTION
COIL REQUIREMENT!
Failure to follow this Caution could result in property damage or personal injury. 4GXC* and
4MXC* coils installed on upflow furnaces in vertical, horizontal left, or horizontal right
orientations without a factory installed metal drain pan shield must use a MAY*FERCOLKITAA
kit. Coils installed on upflow furnaces must have drain pans that are suitable for 400° F
18-CE18D1-1A-EN
(205°C) or have a metal drain pan shield. Downflow furnaces do not require a metal drain pan
shield or the use of the MAY*FERCOLKITAA kit. See Installer's Guide for more information.
S S A A F F E E T T Y Y W W A A R R N N I I N N G G
Only qualified personnel should install and service the equipment. The installation, starting up, and servicing of heating, ventilating, and air-conditioning
equipment can be hazardous and requires specific knowledge and training. Improperly installed, adjusted or altered equipment by an unqualified person
could result in death or serious injury. When working on the equipment, observe all precautions in the literature and on the tags, stickers, and labels that
are attached to the equipment.
1 1 8 8 - - C C E E 1 1 8 8 D D 1 1 - - 1 1 A A - - E E N N
March 2021
(b)
Use with
All Upflow Furnaces
All Furnaces
All Furnaces
All Furnaces
All Furnaces
All Furnaces
B Cabinet Upflow Furnaces
C Cabinet Upflow Furnaces
D Cabinet Upflow Furnaces
All Downflow Furnaces
All Downflow Furnaces
All Upflow Furnaces
All Furnaces
All Furnaces
All Furnaces
All Furnaces
representation only. Actual
model may differ in appearance.
9

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents