Trane S9V2B040U3VSAE Installation, Operation And Maintenance Manual page 12

Upflow/horizontal and dedicated downflow gas-fired, direct/non-direct vent, 2-stage condensing variable speed furnaces with variable speed draft inducer, upflow, convertible to horizontal right or horizontal left/downflow only
Table of Contents

Advertisement

P P r r o o d d u u c c t t S S p p e e c c i i f f i i c c a a t t i i o o n n
Model
Type
RATINGS
(c)
1st Stage Input BTUH
1st Stage Capacity BTUH (ICS)
2nd Stage Input BTUH
2nd Stage Capacity BTUH (ICS)
1st Stage Temp. Rise (Min. - Max.) °F
2nd Stage Temp. Rise (Min. - Max.) °F
AFUE (%)
(d)
Return Air Temp. (Min. - Max.) °F
BLOWER DRIVE
Diameter - Width (in.)
No. Used
Speeds (No.)
CFM vs. in. w.g.
Motor HP
R.P.M.
Volts / Ph / Hz
FLA
COMBUSTION FAN - Type
Drive - No. Speeds
Motor RPM
Volts/Ph/Hz
FLA
Inducer Orifice
FILTER - Furnished?
Type Recommended
Hi Vel. (No.-Size-Thk.)
VENT OUTLET DIA - MIN. (in.)
INLET AIR DIA - MIN. (in.)
HEAT EXCHANGER – Type
Fired
Unfired
Gauge (Fired)
ORIFICES - Main
Nat. Gas (Qty. - Drill Size)
Propane Gas (Qty. - Drill Size)
GAS VALVE
PILOT SAFETY DEVICE – TYPE
BURNERS - TYPE - QTY
POWER CONN. - V/Ph/HZ
(f)
Ampacity (Amps)
Max. Overcurrent Protection (Amps)
PIPE CONN. SIZE (IN.)
(a)
Meets Energy Star
(b)
Central Furnace heating designs are certified to ANSI Z21.47 / CSA 2.3 - latest edition.
(c)
For U.S. Applications, above input ratings (BTUH) are up to 2,000 feet, derate 4% per 1,000 feet for elevations above 2,000 feet above sea level. For
Canadian applications, above input ratings (BTUH) are up to 4,500 feet, derate 4% per 1,000 feet for elevations above 4,500 feet above sea level.
(d)
Based on U.S. government standard tests.
(e)
Refer to Vent Length Table in this document.
(f)
The above wiring specifications are in accordance with National Electrical Code; however, installations must comply with local codes.
12
(d)
(e)
(e)
S9V2B080D4VSAC/D
(a)
,
52,000
51,150
80,000
76,900
11 X 8
See Fan Performance Table
33 - 110 / 3 / 60 - 180
0.96
1 - 16 X 25 - 1 in.
409 Stainless Steel
29-4C Stainless Steel
4 - 45
4 - 56
Redundant - Two Stage
Inshot - 4
(b)
S9V2C100D4VSAC/D
Downflow
65,000
64,300
100,000
97,071
30 - 60
35 - 65
97.0
45°F - 80°F
DIRECT
11 X 10
1
Variable
3/4
Variable
120 / 1 / 60
8 / 9.6
Variable Speed
Direct - Variable
1/50 - 5000
0.77
1.05
No
High Velocity
1 - 20 X 25 - 1 in.
2 Round
2 Round
20
5 - 45
5 - 56
120 V SiNi Igniter
Inshot - 5
120 / 1 / 60
10.9 / 12.9
15
1/2
S9V2-VS-SVX001-1B-EN
(a)
,
(b)

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents