4
ACCESSORIES
4.1
Power Supply and Connecting Cables
4.1.1
Power Supply for Power Bar
Internal: The internal electricity wiring is connected to a terminal in the Power bar.
External: A power cord to supply power is not included. Provide a sufficient connection to mains.
For more information, see 15.1 Cable Plans.
Warning!
Only trained personnel, such as electricians or NEC personnel, may
connect the internal power supply to mains power supply.
4.1.2
Signal Cable
Internal: The modules are connected via the delivered CAT cables between the Hub boards,
which also forwards the signal to the next modules.
External: FE Series to NovaStar Controller: The FE Series comes with signal cables (FTP
Cat5e) to connect data output of the NovaStar Controller to the Ethernet port on the first Hub
board of each column. For more information, see 15.1 Cable Plans.
External: NovaStar Controller to PC: Signal cables to connect the NovaStar Controller and a
PC are included. Refer to Table 4 to choose the correct signal cable for that task.
Table 4: Compatible Signal Cable (Video Distributor)
DVI single link
Cable included in delivery
4.2
Adjustment plate
When installing cabinets, the horizontal and vertical alignment for the whole LED wall is important
so that the image surface is even – without image distortions or light aberrations.
During installation, the Adjustment plates help to align the cabinets across a given row and with
the neighboring rows. The Adjustment plates line up the connecting edges and surfaces of the
cabinets. They are used at each junction point.
After the installation of the cabinets is finished, remove the Adjustment plates. Otherwise, the
Pixel cards do not fit on the cabinet.
Figure 35: Adjustment plate
HDMI
Cable included in delivery
3G-SDI
Cable not included in delivery
36