Installation - Ingersoll-Rand 2925P1Ti Instructions Manual

Super duty impactools
Hide thumbs Also See for 2925P1Ti:
Table of Contents

Advertisement

Ingersoll-rand No. 50
LUBRICATION
Ingersoll-rand No. 170

INSTALLATION

Main Line(s) Inner Ø
to be 3X Size of
Air Tool's Inlet Ø
To Air
System
To Air
Tool
Emergency
L
Shut-Off
Valve
Lubricator
Regulator
FRL
Drain Regularly
Always use an air line lubricator with these tools.
We recommend the following Filter-Lubricator-Regulator
Unit:
For USA – No. C28–04–FKG0–28
For International – No. C28–C4–FKG0
After each forty–eight hours of operation, or as experience
indicates, inject about 4 cc of Ingersoll–Rand No. 170 Grease.
Branch Line(s) Inner Ø
to be 2X Size of
Air Tool's Inlet Ø
R
F
Filter
Compressor
3
(Dwg. TPD905-2)
Form P7715 Edition 1

Advertisement

Table of Contents
loading

This manual is also suitable for:

2925p3ti2925rbp1ti2925rbp3ti

Table of Contents