E-Mu ProteusX Operation Manual page 94

Table of Contents

Advertisement

6 - Voice Editor / Synthesizer Level
Modulation Cords
Modulation Destinations
Destination
Key Sustain
Fine Pitch
Pitch
Glide
Chorus Amount
Chorus Position ITD
Sample Start
Sample Loop
Sample Retrigger
Filter Frequency
Realtime Resonance
'Filter Resonance
Amp Volume
Amp Pan
Amp Crossfade
Send Main
Send Aux 1-3
Wet/Dry Mix
Amp Envelope Rates
Amp Env. Attack
Amp Env. Decay
Amp Env. Release
Filter Envelope Rates Positive values decrease the rates of all filter envelope stages.
Filt Env Atk, Dcy, Rel
Filter Env. Trigger
Aux. Envelope Rates
Aux Env Atk, Dcy, Rel Same as for Amplifier Envelope parameters. See above.
Aux Env. Trigger
LFO Rate (1 & 2)
LFO Trigger (1 & 2)
Lag Processor (0&1)
Summing Amp
Switch
Absolute Value
Diode
Flip-Flop
Quantizer
Gain 4x
Cord 1 - 36 Amount
94
Description
Holds the envelope generators at the sustain point as long as this value is above zero.
Fine pitch modulation with a maximum range of 1 semitone.
Full range pitch modulation.
Controls the portamento (glide) time.
Controls the amount of voice chorus (doubling).
Controls the Inter-aural Time Delay of voice chorus.
Controls the sample start offset point.
Controls the sample loop length.
A negative-going, zero-crossing value retriggers the sample from the sample start.
Controls the frequency (or morph) of the filter.
Realtime control of filter resonance (Q, gain, body size).
Filter resonance control which is set at note-on time only.
Controls the volume of the voice.
Controls the left/right positioning of the voice.
Controls the RT crossfade of voices so programmed.
Controls the level of the voice sent to the Preset FX and the Main Output.
Controls the level of the voice sent to the Aux Send 1, 2 or 3 FX processors.
Controls the Wet/Dry mix sent to the Preset FX.
Positive values decrease the rates of all amp envelope stages.
Positive values decrease the attack rate of the amp envelope.
Positive values decrease the decay rate of the amp envelope.
Positive values decrease the release rate of the amp envelope.
Same as for Amplifier. See above.
A positive-going, zero-crossing value retriggers the envelope.
Positive values decrease the rates of all Aux. envelope stages.
A positive-going, zero-crossing value retriggers the envelope.
Positive values increase the LFO rate.
A negative-going, zero-crossing value resets the LFO to zero.
Inputs for Lag Processors 0 & 1.
Input to the Summing Amp.
Input to the Switch processor.
Input to the Absolute Value processor.
Input to the Diode processor.
Input to the Flip-Flop processor.
Input to the Quantizer.
See page 151.
Input to the 4x Amplifier.
See page 151.
Controls the amount of PatchCords 1-36.
See page 79.
See page 80.
See page 98.
See page 66.
See page 104.
See page 98.
See page 151.
See page 151.
See page 151.
See page 151.
See page 151.
See page 104.
See page 104.
Proteus X Operation Manual

Advertisement

Table of Contents
loading

Table of Contents