10. INSTALLING THE HIGH-PRESSURE PUMP, COOLANT HOSE AND FITTINGS

WARNING
• When using coolant, check the operating pressure before connecting the coolant hose
and fittings. If the maximum operating pressure of the coolant hose or fittings is
exceeded, they could burst and cause injury.
• Connect the coolant hose and fittings securely. A coolant leak could cause injury or
damage the device.
• When using an oil-based coolant, the coolant may be dispersed as a fine mist that could
ignite. Implement fire prevention measures such as the use of dust collectors and
automatic fire extinguishers.
CAUTION
• A high-pressure pump, filter and high-pressure coolant hoses are required in order to
use this spindle. Procure these items separately before use. Install a relief valve or a
safety valve as a safety measure.
• Install the manifold block in the machine tool, and connect the manifold block to this
spindle using a high-pressure coolant hose. Allow some extra length in the hose to
prevent the hose and fittings from being damaged if the machine tool table is moved.
• The high-pressure pump, filter and high-pressure coolant hose serial numbers are
examples of those that we use. Select and prepare the items with the specifications that
you require. Read each Operation Manual for the high-pressure pump, filter and high-
pressure coolant hose that you use.