10 - 1 Installing and Connecting the High-pressure Pump
(1) Install the manifold block so that it does not interfere with other components in the machine tool.
(2) Install the high-pressure pump, and place the intake filter in the coolant tank of the machine tool.
(3) Install the filter (filtration accuracy of 5 μm or less) and connect it to the high-pressure pump, the
relief valve, and the manifold block with the coolant hose and fittings.
(4) Connect the relief valve to the high-pressure pump or high-pressure pump flow path, and connect
the coolant hose to the discharge side of the relief valve. The coolant hose should be installed so
that the coolant can be discharged into the coolant tank.
Inside the machine tool
G1 / 8 threads
Relief valve
Intake filter
Filter
(Filtration accuracy of 5 μm or less)
Relief valve
32
High-pressure pump
Intake hose
Fig. 8 Coolant hose and fitting connection example
Fig. 9 Reference circuit diagram
φ6 mm
High-pressure coolant hose
Manifold block
Coolant hose and fittings
Manifold block
High-pressure pump
Intake filter
Filter
(Filtration accuracy
of 5 μm or less)
Spindle
High-pressure coolant hose