Hydac CTM-SC-3 Series Installation Manual
Hydac CTM-SC-3 Series Installation Manual

Hydac CTM-SC-3 Series Installation Manual

Long nozzles set

Advertisement

Quick Links

CTM-SC-3xxx
Long nozzles set
Installation Manual
English (translation of original instructions)
Document No. : 4642026a

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the CTM-SC-3 Series and is the answer not in the manual?

Questions and answers

Summary of Contents for Hydac CTM-SC-3 Series

  • Page 1 CTM-SC-3xxx Long nozzles set Installation Manual English (translation of original instructions) Document No. : 4642026a...
  • Page 2 Court of Registration: Saarbrücken, HRB 17216 Executive directors: Mathias Dieter, Dipl.Kfm. Wolfgang Haering CE - Documentation Representative Günter Harge c/o HYDAC International GmbH, Industriegebiet, 66280 Sulzbach / Saar Germany Telephone: +49 6897 509 1511 Fax: +49 6897 509 1394 E-mail: guenter.harge@hydac.com UKCA –...
  • Page 3: Table Of Contents

    HYDAC FILTER SYSTEMS GMBH Table of Contents Table of Contents General ........................ 4 Target group of the manual ................ 4 Illustrations in the manual................ 5 1.2.1 Illustration on the title page .............. 5 1.2.2 Representation of requirements............ 6 1.2.3 Representation of procedural instructions ......... 6 1.2.4 Representation of intermediate results/results........ 7...
  • Page 4: General

    1 | General HYDAC FILTER SYSTEMS GMBH 1 General Before you use this product for the first time, read this manual at least up to the chapter "Operation". If you would like to carry out maintenance or troubleshooting, you can find the procedure in the respective chapters.
  • Page 5: Illustrations In The Manual

    HYDAC FILTER SYSTEMS GMBH General | 1 1.2 Illustrations in the manual You will find illustrations in this manual. You can find details regarding these in the following chapters. 1.2.1 Illustration on the title page You will find the following information on the title page of this...
  • Page 6: Representation Of Requirements

    1 | General HYDAC FILTER SYSTEMS GMBH The document no. with the index (4) is meant for identifying and reordering the manual. The index is incremented every time the manual is revised or changed. The manual contains a table of contents, a list of tables and figures, an index and a glossary.
  • Page 7: Representation Of Intermediate Results/Results

    HYDAC FILTER SYSTEMS GMBH General | 1 – Rinse the product. 1.2.4 Representation of intermediate results/results In the case of some activities, it is necessary to carry out work steps with intermediate results and end results. Intermediate results are the consequence of activities; they are marked with an indented arrow.
  • Page 8: Supplementary Symbols

    1 | General HYDAC FILTER SYSTEMS GMBH 1.2.5 Supplementary symbols You will find the following symbols in the manual as additional details: Cross reference to a page / a chapter / a section or u ## another document. Glossary Terms in grey are explained in detail in the glossary, a chapter at the end of the manual.
  • Page 9: Signal Words And Their Meaning In The General Safety Information

    HYDAC FILTER SYSTEMS GMBH General | 1 1.2.7 Signal words and their meaning in the general safety information In these instructions you will find the following signal words: DANGER DANGER – The signal word indicates a hazardous situation with a high level of risk, which, if not avoided, will result lethal or serious injury.
  • Page 10: Exclusion Of Liability / Warranty

    They are made available to you at the conclusion of the contract at the latest. In addition, you will find these under www.hydac.com -> General terms and conditions . This manual was prepared to the best of our knowledge.
  • Page 11: Product And Technical Specifications

    HYDAC FILTER SYSTEMS GMBH Product and technical specifications | 2 2 Product and technical specifications This set of long nozzles were developed for sampling large containers / tanks. Nozzles with different spray patterns can be connected for the sampling process. The extension is suitable for all nozzles.
  • Page 12 2 | Product and technical specifications HYDAC FILTER SYSTEMS GMBH - 1x Installation manual (this document) 12 / 24 MA LongNozzlesSet 4642026a en-us web...
  • Page 13: Intended Use

    2.3 Improper use or use deviating from intended use Any other use or extended use shall not be considered intended use. HYDAC FILTER SYSTEMS GMBH will assume no liability for any damage resulting from such use. This risk is borne solely by the owner.
  • Page 14: Decoding The Model Code

    2 | Product and technical specifications HYDAC FILTER SYSTEMS GMBH – Improperly performed repair work. 2.4 Decoding the model code Details for identification of long nozzles are given on the product. Fig. 3: Decoding the model code For details on model code, see Model code [} 15].
  • Page 15: Model Code

    HYDAC FILTER SYSTEMS GMBH Product and technical specifications | 2 2.4.1 Model code The CTL is defined by the following model code: CTL - 1 - Z - Z - Z - 10 - 2 - Z - Z - Z - Z - 2...
  • Page 16: Technical Data

    2 | Product and technical specifications HYDAC FILTER SYSTEMS GMBH 2.5 Technical data If you are aware of the technical data of the product, you will be able to use it optimally. This chapter provides the technical data of the product:...
  • Page 17 HYDAC FILTER SYSTEMS GMBH Product and technical specifications | 2 Technical data Suction lance Permissible test liquid Water with surfactants Permitted supply module CTM-SC-3000 Flow ≤ 10 l/min Connection M18x1.5, (12L) according to ISO 8434-1 Length 1000 mm without handle piece permissible ph-values 6 … 10, no fully desalinated water (VE water) Tab. 5: Technical data - Suction lance...
  • Page 18: Connecting The Plastic Pipe

    3 | Connecting the plastic pipe HYDAC FILTER SYSTEMS GMBH 3 Connecting the plastic pipe An optimally assembled and installed product ensures a safe and continuous operation. Specialist personnel – General / Operating personnel These persons have a specialist training and several years of work experience.
  • Page 19 HYDAC FILTER SYSTEMS GMBH Connecting the plastic pipe | 3 3. Connect the suction lance with the connection R. 4. Plug the coding connector into the electrical connection. O The suction lance and the long nozzle are connected to the supply module.
  • Page 20: Operation

    4 | Operation HYDAC FILTER SYSTEMS GMBH 4 Operation Procedures, notes and tips for optimum, fault-free operation can be found in this chapter. To change the long nozzles, pull the ring of the quick release coupling backwards. Insert the desired long nozzles and loosen the ring of the quick release coupling again.
  • Page 21 HYDAC FILTER SYSTEMS GMBH Operation | 4 Fig. 6: Long ridged nozzle Fig. 7: Long nozzle shield 5. Suction off the analysis fluid with the suction lance from the tank / container fully. O The extraction is complete. Fig. 8: Suction lance MA LongNozzlesSet 4642026a en-us web...
  • Page 22: Decommissioning / Disposal

    5 | Decommissioning / Disposal HYDAC FILTER SYSTEMS GMBH 5 Decommissioning / Disposal In the following chapters, you will be provided with information regarding temporary shutdown/final decommissioning and disposal of the product. 5.1 Temporary shutdown If the product is being temporarily shut down, the following...
  • Page 23: Index

    HYDAC FILTER SYSTEMS GMBH Index Index Long nozzle shield  16 Long open nozzle  16 Disposal Long ridged nozzle  16 Disposal  22 Suction lance  17 Recycling  22 Documentation Representative  2 UKCA Authorized representative  2 Exclusion of Liability  10 Warranty  10 HYDAC General Terms and Conditions  10...
  • Page 24 www.hydac.com...

Table of Contents