SAVE THESE INSTRUCTIONS. This manual contains important safety precautions which should be read and understood before operating the product. Failure to do
so could result in serious injury. This manual should remain with the product.
Specifications, descriptions and illustrations in this manual are as accurate as known at the time of publication, but are subject to change without notice.
REV 20220916

Advertisement

Table of Contents
loading

Summary of Contents for Champion Global Power Equipment 500988-UK

  • Page 1 OPERATOR'S MANUAL MODEL #500988-UK 3500W RATED DUAL FUEL INVERTER GENERATOR REGISTER YOUR PRODUCT ONLINE at championpowerequipment.co.uk +44(0)-1942-715-407 or visit www.championpowerequipment.co.uk SAVE THESE INSTRUCTIONS. This manual contains important safety precautions which should be read and understood before operating the product. Failure to do so could result in serious injury.
  • Page 2 CARBON MONOXIDE SAFETY: THE BIG PICTURE As the only safe way to use a portable generator, taking your generator outside is absolutely mandatory to keep your family safe from carbon monoxide. But there’s even more you can do. By educating yourself about all carbon monoxide risks, you’ll be better prepared to protect your family from this colorless, oderless threat.
  • Page 3: Table Of Contents

    TAbLE OF CONTENTS 500988-UK - 3500W RATED DUAL FUEL INVERTER GENERATOR TAbLE OF CONTENTS Generator Battery ..........Adjusting the Governor ........... Introduction ...........
  • Page 4: Introduction

    INTRODUCTION 500988-UK - 3500W RATED DUAL FUEL INVERTER GENERATOR INTRODUCTION SAFETY DEFINITIONS Congratulations on your purchase of a Champion Power Equipment The purpose of safety symbols is to attract your attention to possible dangers. The safety symbols, and their explanations, (CPE) product.
  • Page 5: Important Safety Instructions

    IMPORTANT SAFETY INSTRUCTIONS 500988-UK - 3500W RATED DUAL FUEL INVERTER GENERATOR IMPORTANT SAFETY INSTRUCTIONS DANGER  Operate equipment with guards in place. DANGER  Rotating parts can entangle hands, feet, hair, clothing and/or Generator exhaust contains carbon monoxide, a colorless, accessories.
  • Page 6 IMPORTANT SAFETY INSTRUCTIONS 500988-UK - 3500W RATED DUAL FUEL INVERTER GENERATOR WARNING CAUTION   Spark from removed spark plug wire can result in fire or Exceeding the generator’s running capacity can damage the electrical shock. generator and/or electrical devices connected to it.
  • Page 7: Fuel Safety

    IMPORTANT SAFETY INSTRUCTIONS 500988-UK - 3500W RATED DUAL FUEL INVERTER GENERATOR Fuel Safety DO NOT pump petrol directly into the generator at the gas station. Always use an approved container to transfer the fuel to the generator. DANGER  DO NOT overfill the gasoline tank.
  • Page 8: Lithium-Ion Battery Safety

    IMPORTANT SAFETY INSTRUCTIONS 500988-UK - 3500W RATED DUAL FUEL INVERTER GENERATOR Lithium-ion battery Safety When storing the generator/battery: – Always check that the battery connectors between the inverter Electrolyte inside the battery is harmful to skin and eyes. If the and the battery are unplugged and placed away from the battery leaks and electrolyte gets in your eyes, do not rub them.
  • Page 9: Safety And Dataplate Labels

    IMPORTANT SAFETY INSTRUCTIONS 500988-UK - 3500W RATED DUAL FUEL INVERTER GENERATOR Safety and Dataplate Labels These labels warn you of potential hazards that can cause serious injury. Read them carefully. If a label comes off or becomes hard to read, contact Technical Support Team for possible replacement.
  • Page 10: Safety Symbols

    IMPORTANT SAFETY INSTRUCTIONS 500988-UK - 3500W RATED DUAL FUEL INVERTER GENERATOR Safety Symbols Some of the following symbols may be used on this product. Please study them and learn their meaning. Proper interpretation of these symbols will allow you to more safely operate the product.
  • Page 11 IMPORTANT SAFETY INSTRUCTIONS 500988-UK - 3500W RATED DUAL FUEL INVERTER GENERATOR SYMBOL MEANING Read Operator’s Manual. To reduce the risk of injury, user must read and understand operator’s manual before using this product. This product uses lithium-ion (Li-ion) batteries. Local, state, or federal laws may prohibit disposal of batteries in ordinary trash.
  • Page 12: Operation Symbols

    IMPORTANT SAFETY INSTRUCTIONS 500988-UK - 3500W RATED DUAL FUEL INVERTER GENERATOR Operation Symbols Some of the following symbols may be used on this product. Please study them and learn their meaning. Proper interpretation of these symbols will allow you to more safely operate the product.
  • Page 13: Quick Start Label Symbols

    IMPORTANT SAFETY INSTRUCTIONS 500988-UK - 3500W RATED DUAL FUEL INVERTER GENERATOR Quick Start Label Symbols Some of the following symbols may be used on this product. Please study them and learn their meaning. Proper interpretation of these symbols will allow you to more safely operate the product.
  • Page 14: Controls And Features

    CONTROLS AND FEATURES 500988-UK - 3500W RATED DUAL FUEL INVERTER GENERATOR CONTROLS AND FEATURES Read this operator’s manual before operating your generator. Familiarize yourself with the location and function of the controls and features. Save this manual for future reference.
  • Page 15: Control Panel

    CONTROLS AND FEATURES 500988-UK - 3500W RATED DUAL FUEL INVERTER GENERATOR Control Panel 1. Intelligauge with Power Meter – See Intelligauge with RECEPTACLES Power Meter section. (2×) 240V AC, 13A 2. Ignition Switch – Used to START the generator. May be used to supply electrical power for 3.
  • Page 16: Intelligauge With Power Meter

    CONTROLS AND FEATURES 500988-UK - 3500W RATED DUAL FUEL INVERTER GENERATOR Intelligauge with Power Meter The meter is divided into two separate displays. The LCD displays each mode for several seconds and then automatically cycles through. The Power Meter LED displays output in percent (%) with 100% at the top.
  • Page 17: Parts Included

    CONTROLS AND FEATURES 500988-UK - 3500W RATED DUAL FUEL INVERTER GENERATOR Parts Included Accessories Oil Funnel ............12VDC USB Adapter ..........12VDC Battery Charging Cable ........
  • Page 18: Assembly

    IMPORTANT ASSEMbLY 500988-UK - 3500W RATED DUAL FUEL INVERTER GENERATOR ASSEMbLY Connect the battery 1. Remove the non recoil side maintenance cover by removing Your generator requires some assembly. It must be properly the two screws with a phillips head screw driver serviced with fuel and oil before operation.
  • Page 19 ASSEMbLY 500988-UK - 3500W RATED DUAL FUEL INVERTER GENERATOR OIL DIP STICK OIL DIP STICK Recommended Engine Oil Type 10W-30 5W-30 10W-40 5W-30 Full Synthetic °F °C -28.9 -17.8 -6.7 15.6 26.7 37.8 48.9 Ambient temperature NOTICE  1. Place the generator on a flat, level surface.
  • Page 20: Add Fuel: Petrol Y

    ASSEMbLY 500988-UK - 3500W RATED DUAL FUEL INVERTER GENERATOR Add Fuel: Petrol Empty Full DANGER  Petrol vapors are highly flammable and extremely explosive. DO NOT light or smoke cigarettes. Fire or explosion can cause severe burns or death. Only fill or drain fuel outdoors in a well-ventilated area. DO NOT pump petrol directly into the generator.
  • Page 21: Add Fuel: Propane (Lpg)

    ASSEMbLY 500988-UK - 3500W RATED DUAL FUEL INVERTER GENERATOR NOTICE  The generator engine works well with 10% or less ethanol blended petrol. When using ethanol-gasoline blends there are some issues worth noting: – Ethanol-petrol blends can absorb more water than petrol alone.
  • Page 22: Grounding

    OPERATION 500988-UK - 3500W RATED DUAL FUEL INVERTER GENERATOR OPERATION WARNING  If there is a strong smell of LPG: Close valve on the cylinder. Generator Location Check all connections for leaks by wetting the fittings with a solution of soap and water. Bubbles which appear or bubbles WARNING ...
  • Page 23: Surge Protection

    OPERATION 500988-UK - 3500W RATED DUAL FUEL INVERTER GENERATOR Manual Start WARNING  Cold Engine Start During operation the muffler and exhaust fumes will become 3. Move the EZ Start dial to the “CHOKE” position. hot. If adequate cooling and breathing space are not supplied, or if the generator is blocked or enclosed, temperatures can become extremely heated and may lead to fire.Never modify...
  • Page 24 OPERATION 500988-UK - 3500W RATED DUAL FUEL INVERTER GENERATOR 5. Do not over-choke. As soon as engine starts, turn the EZ 4. Pull the recoil cord slowly until resistance is felt (compression Start dial to the “RUN” position. point), then release the cord slowly back use one strong rapid pull to start, if the generator does not start repeat process.
  • Page 25: Starting The Engine: Propane (Lpg)

    OPERATION 500988-UK - 3500W RATED DUAL FUEL INVERTER GENERATOR NOTICE  5. Slowly pull the starter cord 3-5 times to prime the engine. If the engine starts but does not continue to run, make certain that the generator is on a flat, level surface. The engine is equipped with a low oil sensor that will prevent the engine from running when the oil level falls below a critical threshold.
  • Page 26 OPERATION 500988-UK - 3500W RATED DUAL FUEL INVERTER GENERATOR Warm Engine Start 4. Turn the EZ Start dial to the “RUN” position. 6. Do not over-choke. As soon as engine starts, turn the EZ Start dial to the “RUN” position.
  • Page 27: Connecting Electrical Loads

    OPERATION 500988-UK - 3500W RATED DUAL FUEL INVERTER GENERATOR WARNING  Always remember to plug your appliances directly into the generator and do not plug the generator power cord into any electrical outlet or connect to the circuit breaker panel in your home.
  • Page 28: Eco (Economy) Mode

    OPERATION 500988-UK - 3500W RATED DUAL FUEL INVERTER GENERATOR Power Management CAUTION  Use the following formula to convert voltage and amperage to For periods of high electrical load or momentary fluctuations, watts: the Eco Mode should be off. Volts × Amps = Watts...
  • Page 29: Parallel Operation

    Parallel Operation This section has had a template updated. Use below text The Champion model 500988-UK is parallel ready and can be operated in parallel with another Champion unit to increase the total available electrical power. A Champion parallel kit (optional equipment) is required for parallel operation.
  • Page 30: Moving The Generator

    MAINTENANCE 500988-UK - 3500W RATED DUAL FUEL INVERTER GENERATOR Operation at High Altitude NOTICE  The density of air at high altitudes is lower than at sea level. If the generator will not be used for a period of two (2) weeks...
  • Page 31: Cleaning The Generator

    MAINTENANCE 500988-UK - 3500W RATED DUAL FUEL INVERTER GENERATOR DRAIN PLUG WARNING  Improper maintenance will void your warranty. The owner/ user is responsible for service and maintenance of the generator including oil, spark plug, spark arrestor, filters and valve adjustments. Improper servicing or maintenance of this generator will void any warranty.
  • Page 32: Cleaning The Air Filter

    MAINTENANCE 500988-UK - 3500W RATED DUAL FUEL INVERTER GENERATOR 4. Inspect the electrode on the plug. It must be clean and not 3. Remove the foam element. worn to produce the spark required for ignition. 4. Wash in liquid detergent and water. Squeeze thoroughly dry in 5.
  • Page 33: Generator Battery

    MAINTENANCE 500988-UK - 3500W RATED DUAL FUEL INVERTER GENERATOR 2. Charge battery following the battery charger’s instructions. NOTICE  3. After charging, leave the battery for 0.5 to 1 hour before Federal and local laws and administrative requirements checking the voltage. If the voltage is less than 12.8 volts, indicate when and where spark arrestors are required.
  • Page 34: Storage

    STORAGE 500988-UK - 3500W RATED DUAL FUEL INVERTER GENERATOR STORAGE FIRST 5 HOURS (BREAK IN) — Change oil WARNING  To avoid accidental or unintended ignition of your generator EVERY 50 HOURS OR ANNUALLY during periods of storage, the following precautions should be —...
  • Page 35: Long Term Storage (More Than 1 Year)

    STORAGE 500988-UK - 3500W RATED DUAL FUEL INVERTER GENERATOR Removing from Storage 4. Run the generator for 10 minutes so the treated petrol cycles through the fuel system and carburetor. NOTICE  5. Turn the EZ Start dial to the “STOP” position.
  • Page 36: Specifications

    SPECIFICATIONS 500988-UK - 3500W RATED DUAL FUEL INVERTER GENERATOR SPECIFICATIONS Oil Specifications DO NOT OVERFILL. Generator Specifications Type ..........*See following chart Generator Model ........
  • Page 37: Wiring Diagram

    SPECIFICATIONS 500988-UK - 3500W RATED DUAL FUEL INVERTER GENERATOR Engine Parts List Part Number Description Qty. 16002-Z950110- Carburetor Insulator 00A0 Gasket 16003-Z1D0110- Carburetor Insulator 00A0 Plate 16001-Z010110- Carburetor Gasket 00A0 16100-Z3R0310- Carburetor Assembly 00A1 16112-Z010110- Seal Ring, Float 0000 16161-Z152410-...
  • Page 38: Parts Diagram Figure A

    TROUbLESHOOTING 500988-UK - 3500W RATED DUAL FUEL INVERTER GENERATOR TROUbLESHOOTING Problem Cause Solution No fuel. Add fuel. Faulty spark plug. Clean and adjust spark plug or replace. Fill crankcase to the proper level. Low oil level. Place generator on a flat, level surface.
  • Page 39: Parts List

    TROUbLESHOOTING 500988-UK - 3500W RATED DUAL FUEL INVERTER GENERATOR UK DECLARATION OF CONFORMITY CHAMPION POWER EQUIPMENT, INC. 12039 SMITH AVENUE, SANTA FE SPRINGS, CA 90670, USA Hereby declare that the following Appliance complies with the appropriate basic safety and health requirements of the UKCA Directives (see item 3 &...
  • Page 40 TROUbLESHOOTING 500988-UK - 3500W RATED DUAL FUEL INVERTER GENERATOR 5. Responsible for documentation: CHAMPION POWER EQUIPMENT, INC. Address: 12039 SMITH AVENUE, SANTA FE SPRINGS, CA 90670, USA 6. Person responsible for compiling the technical files established within the UK Name, Surname: Winch Solutions LTD...
  • Page 41: Parts Diagram Figure E

    WARRANTY 500988-UK - 3500W RATED DUAL FUEL INVERTER GENERATOR WARRANTY* required to be performed at a facility or by a person authorized by CPE. CHAMPION POWER EQUIPMENT 3 YEAR LIMITED WARRANTY Other Exclusions This warranty excludes: Warranty Qualifications – Cosmetic defects such as paint, decals, etc.