Technical data
4
Technical data
4.1
Definitions
4.1.1 Technical terms
4.2
Properties
Name
Signal period
Output signal
Termination resistor
Accuracy
Repeatability
Resolution
Power supply
Connection cable
22
───
All details relate to an ambient temperature of 40 °C.
This chapter provides information on various technical terms and
their meaning.
Signal period
Duration/distance of a signal period.
Accuracy
Maximum deviation between the set position and the
actual position.
Repeatability
Degree of accuracy by which the positioning accuracy can be re-
duced during a repeated movement.
Resolution
Indicates the smallest position increment.
Value / property
Pole pair distance 24 mm
Analog signal 1 V
, sine-cosine
pp
R = 120 Ω
< 100 µm
The prerequisite is the precise installation of the magnetic plates with an ac-
curacy of ± 20 µm and offset, phase and amplitude compensation.
< 50 µm
5...10 µm
5 V DC
8-core
with twisted pairs
material PUR
UL-certified
outer diameter 6.8 ± 0.2 mm
AL8200