Transport And Storage; Conditions; Transport; Long-Term Storage - Beckhoff AL8200 Operating Instructions Manual

Magnetic encoder system for linear motors al8000
Table of Contents

Advertisement

6

Transport and storage

6.1

Conditions

6.2

Transport

6.3

Long-term storage

Version: 1.0
Avoid damage to the encoders and resulting loss of warranty
Observe the conditions and the following chapters on transport and
storage.
Failure to observe the conditions may result in damage to the mag-
netic encoder system and void the warranty.
During transport and storage, ensure that the magnetic encoder sys-
tems are not damaged. Observe the specifications in the following
chapters and comply with the following conditions:
• Climate category: 3K3 according to EN 60721
• Temperature: -25 °C to +70 °C, maximum fluctuation 20 K per
hour
• Humidity: relative humidity 5 % to 95 %, no condensation
• Use of suitable means of transport
• Use of the vendor's original packaging
Product designation
AL8200-0000-0000
AL8200-0001-0000
The following options are available for transporting a single encoder
system:
• Without tools, by hand
Observe storage conditions
Unlimited storage of magnetic encoder systems possible. Ensure
that low air humidity is maintained when storing feedback systems.
Failure to observe this may result in changes in the properties of
the cables or the sealing compound.
Perform recurring inspections
Check the encoder systems for proper condition every six months.
Damage to the encoder system or maintenance work not carried
out on the machine / system will affect the service life of the in-
stalled components and parts.
Prevent the formation of condensation
Keep the ambient temperature constant. Avoid solar radiation and
high air humidity.
Condensation water can lead to damage during subsequent opera-
tion, calcification or rust formation.
AL8200
Transport and storage
Dimensions individual packaging
[mm]
390x217x127
240x140x50
───
25

Advertisement