10 Maintenance and cleaning

10.1 Cleaning agents

10.1.1 Not applicable

Version: 1.0
WARNING
Refrain from cleaning work during operation
Carrying cleaning work during operation can lead to serious or fa-
tal injuries.
• For cleaning work, bring the connected motors and the ma-
chine into a safe, de-energized state.
Do not immerse or spray the encoder system
Wipe off the encoder system only with a cleaning agent and a
cloth.
Due to impermissible solutions, cleaning by immersion can lead to
damage to the surface and the encoder system as well as to leak-
tightness problems.
Magnetic encoder systems are basically maintenance-free.
treme soiling can lead to failure.
Clean the components carefully with a damp cloth or a brush.
Use grease-dissolving and non-aggressive cleaning agents such as
isopropanol for cleaning. You will also receive information about
non-approved cleaning agents.
Cleaning agents
Aniline hydrochloride
Bromine
Sodium hypochlorite; bleaching
solution
Mercury (II) chloride
Hydrochloric acid
AL8200
Maintenance and cleaning
Chemical formula
C
H
NH
HCI
6
5
2
Br
2
NaCIO
HgCl
2
HCI
Ex-
───
37