according to collecting interval. If threshold is triggered, it uploads the current data once
instantly.
Note:
threshold setting is only for bin mode and standard mode.
Parameters
Collecting interval to detect distance, this should be smaller than or equal
Collecting Interval
to reporting interval.
Threshold Dismiss
When the collected value changes from outside the threshold to within the
Report
threshold, a threshold release packet will be reported.
3.5 Maintenance
3.5.1 Upgrade
1. Download firmware from Milesight website to your smartphone.
2. Open Toolbox App, go to Device > Maintenance and click Browse to import firmware and
upgrade the device.
Note:
1) Operation on ToolBox is not supported during a firmware upgrade.
2) Only Android version ToolBox supports the upgrade feature.