3.3 Basic Settings
Go to Device > Setting > General Settings of ToolBox App to change the reporting interval, etc.
Parameters
Device Mode
Select from Standard Mode, Bin Mode or Parking Lot Mode.
Reporting interval of transmitting data to network server.
Standard Mode: 10 minutes as default;
Reporting Interval
Bin mode: 20 minutes as default;
Parking Lot Mode: 1080 minutes as default. If the sensor detects the
occupancy status change, it will report immediately.
Collecting interval of measuring distance on Parking Lot Mode. Default:
Collecting Interval
20s; Range: 1~600s
Set the installation height between device and ground when in Parking Lot
Mode. Default: 3m; Range: 0.030~4.500m
Threshold Distance Value (Δ) is 1m as default, triggering logic is as below:
Installation Height
Installation Height - Detected Distance < Δ, the sensor will reports
occupied immediately.
Installation Height - Distance Distance > Δ, the sensor will reports
vacant immediately.
Description
10
Need help?
Do you have a question about the EM400-MUD and is the answer not in the manual?