1. INTRODUCTION
1. INTRODUCTION
1)
1)
MACHINE IN GENERAL
MACHINE IN GENERAL
(1)
If even a minor fault is left intact and operation is continued, a fatal failure may be caused,
entailing a large sum of expenses and long hours of restoration.
Therefore when even a small trouble occurs, do not rely on your intuition and experience, but look
for the cause based on the troubleshooting principle and perform maintenance and adjustment to
prevent major failure from occurring. Keep in mind that a fault results from a combination of
different causes.
(2)
The following lists up commonly occurring faults and possible causes with this machine. For the
troubleshooting of the engine, refer to the coming troubleshooting and repair.
(3)
When carrying out troubleshooting, do not hurry to disassemble the components.
It will become impossible to find the cause of the problem.
(4)
Ask user or operator the following.
Was there any strange thing about machine before failure occurred?
Under what conditions did the failure occur?
Have any repairs been carried out before the failure?
(5)
Check before troubleshooting.
Check oil and fuel level.
Check for any external leakage of oil from components.
Check for loose or damage of wiring and connections.
2)
2)
MACHINE STATUS MONITORING ON THE CLUSTER
MACHINE STATUS MONITORING ON THE CLUSTER (CLUSTER TYPE 1)
(1)
The machine status such as the engine rpm, oil temperature, voltage and pressure etc. can be
checked by this menu.
Analog 1
Analog 1
(2)
(2)
Specification
Specification
No.
Note 1
Pilot pump pressure
Note 2
Swing pilot pressure
Note 3
Boom up pilot pressure
Note 4
P1 pump control pressure
Note 5
P2 pump control pressure
Note 6
Pump 1 pressure
Note 6
Note 3
Note 4
Note 5
Note 2
Note 1
Description
6-4
Analog 2
Analog 2
3009SH6HS01
Specifi cation
+2
40
bar
0
0~40 bar
0~40 bar
0~25 bar
0~25 bar
350 bar