Group 3 Electrical Component Specification - Hyundai R480LC-9S Service Manual

Crawler excavator
Table of Contents

Advertisement

GROUP 3 ELECTRICAL COMPONENT SPECIFICATION

GROUP 3 ELECTRICAL COMPONENT SPECIFICATION
Part name
Battery
Battery relay
Pre-heat relay
Start key
CS-2
Pressure
sensor
CD-6 CD-7 CD-24
(cluster type 1)
CD-31 CD-32 CD-42
CD-43 CD-44 CD-69
CD-70 CD-71
Pressure
sensor
(cluster type 2)
CD-6 CD-7 CD-31
CD-42 CD-43 CD-44
Symbol
CR-1
CR-24
SUPPLY
A
SIG
B
RETURN
C
CD-7
SUPPLY
A
SIG
B
RETURN
C
CD-7
Specifications
※ Check specific gravity
12V × 100Ah
(2EA)
※ Check coil resistance(M4 to M4)
Rated load :
24V
※ Check contact
100A (continuity)
1000A (30seconds)
※ Check contact
24V 200A
※ Check contact
B-BR : 24V 1A
B-ACC : 24V 10A
B-ST
: 24V 40A
※ Check contact
8~30V
※ Check contact
8~30V
4-38
Check
1.280 over
: Over charged
1.280 ~ 1.250 : Normal
1.250 below : Recharging
Normal : About 50Ω
Normal : ∞Ω
Normal : 0.942Ω
(For terminal 1-GND)
OFF : ∞Ω(for each terminal)
ON : 0Ω(for terminal 1-3 and 1-2)
START : 0Ω(for terminal 1-5)
Normal : 0.1Ω
Normal : 0.1Ω