Volvo Penta TAD1381VE Operator's Manual page 26

13l
Table of Contents

Advertisement

Presentation
1. From engine
2. To tank
24
Heating
®
Because AdBlue
/DEF solution freezes at around –
11 °C (12.2 °F) the tank is equipped with a heating coil
that uses engine coolant. A solenoid valve controls the
flow of coolant. The hoses between the tank, pump and
injectors are electrically heated and the hose
connections are equipped with extra insulation.
There is a temperature sensor in the tank that transmits
a signal to the control unit so that the pump cannot start
®
until the AdBlue
/DEF solution is fluid. The standard
system can handle thawing from -40 °C (-40 °F). The
system is emptied at shut down in order to prevent
expansion damage due to freezing.
IMPORTANT:
Hoses must be handled carefully and not twisted or
bent excessively in order to avoid damaging the
heating system.
Storage
IMPORTANT:
To prevent breakdown and evaporation during
longterm storage, AdBlue®/DEF may not be stored at
temperatures higher than 25 °C (77 °F) or in direct
sunlight.
Remember that the solution expands upon freezing
and to leave room for expansion in the tank when
storing in spaces where there is a risk of freezing.
47713625 06-2021 © AB VOLVO PENTA

Advertisement

Table of Contents
loading

This manual is also suitable for:

Tad1382veTad1383veTad1384veTad1385ve

Table of Contents