Fault handling
42
Regeneration
Only applicable for VE engines
If the control system detects high EATS loads (high
soot level in filter, high sulfur load or HC-formation) the
engine is in need of regeneration. When requested, a
parked regeneration should be performed as soon as
possible. The regeneration will last for approximately
60 minutes and it should not be aborted.
Regeneration needed
•
The warning symbol shines with a
solid yellow light.
P0002361
•
The PCD symbol flashes.
CAUTION!
During regeneration the exhaust gases gets hot.
Make sure the vehicle is parked in a safe environment
before regeneration is started.
NOTICE! Repeated regeneration interruptions will
force the system in derate and Volvo Penta diagnostic
tool is required to perform a service regeneration.
Engine derate information
If the soot load reaches >80%, full derate will be
applied. Full derate keeps engine speed below 1500
rpm and torque reduction.
If exhaust temperature gets above 440 °C for more
than 300 seconds, EATS fully loaded with sulfur
combined with continues high-power outtake can lead
to maximum 28% derate. Such an event will be
followed by a fault code and request parked sulfur
regeneration.
Regeneration calibration settings
•
Target temp (VE), for soot/deposit regen is 470–490
°C and takes 40–60 min.
For genset: Soot 60 min temperature elevated.
•
Target temp for HC regen is 350–400 °C and takes
about 17 min.
•
Target temp (VE), sulfur parked regeneration is
~530 °C inside EATS and takes 75 min.
47713625 06-2021 © AB VOLVO PENTA