AdBlue/DEF tank level
1 When the level in the tank falls to 15%, a yellow warning indicator is lit in combination with a solid NCD
symbol.
2 When the tank level reaches 6%, the warning indicator turns red and the NCD symbol starts to flash. After
7 minutes the engine is stopped.
3 If the engine is started when the tank level falls below 6%, the engine will only run at idle speed.
4 To revert the engine to full power, the tank level must be above 12%. To exit the inducement, the tank level
must be above 21%.
AdBlue/DEF, dosing and quality
A
Engine rpm and torque
B
Time axis
1 When a fault is detected, a yellow warning indicator is lit in combination with a solid NCD symbol.
2 If the fault is not resolved within 10 hours the warning indicator turns red and the NCD symbol starts to flash.
After 7 minutes the engine will be stopped.
3 If the engine has stopped it is possible to manually override the system actions and run the engine at full
power for 3 x 30 minutes. After 30 minutes the engine shuts down again. Each 30-minute period requires a
manual activation.
4 When the faults are remedied the engine will revert to full power.
47713625 06-2021 © AB VOLVO PENTA

EATS Inducements, GE-engines

Fault handling