Figure 23 Replacing The Front Bezel - Nortel Contivity 600 Installing

Hardware options for the contivity secure ip services gateway
Hide thumbs Also See for Contivity 600:
Table of Contents

Advertisement

62 Chapter 4 Contivity 1740 option installation
7
Lower the new option card into the slot and gently press the connector into the
slot.
Make sure that the card is seated firmly in the slot. If the card is not seated
properly, it will not work.
8
Replace the screw that secures the card to the slot
9
Replace the top cover on the chassis (see
a
b Using a screwdriver, insert and tighten the 4 screws that secure the cover
10 If the Contivity 1740 is installed in an equipment rack, mount it in the rack.
a
b Insert one of the panhead screws through the bottom hole on each side of
11 Replace the front bezel
a
b Using a screwdriver, tighten the 2 screws to secure the bezel to the

Figure 23 Replacing the front bezel

302283-K Rev 00
Hold the cover at an angle and slide it onto the chassis.
to the chassis.
Set the Contivity 1740 on the rack-mount shelf in the rack.
the shelf into the hole in the rack and tighten the screws.
(Figure
Hold the bezel by its two handles and push it onto the chassis.
chassis.
Figure 19 on page
23).
Press here
(Figure
22).
56).
CS260005D