Firmware
The firmware for SSE-G3748 series Ethernet switches resides on a chip on the PCB.
Firmware Upgrading Procedures
SONiC firmware can be installed in one of two methods:
1. From within a running SONiC image using the sonic-installer CLI command.
2. From ONIE
Please refer the Supermicro SONiC configuration guide document for details about each of
the above mentioned methods.
3.2 SSE-G3748/D/R/DR-SMIS
Installation
To install SSE-G3748/D/R/DR-SMIS Ethernet switches, use the procedure below.
Installing the Switch
1. Carefully unpack the switch from its shipping container and verify that all parts are
present.
2. Install the mounting ears onto the side of the switch using a screwdriver.
3. Mount the switch into your rack assembly.
Configuring the Switch Module
The SSE-G3748/D/R/DR-SMIS Ethernet switch module can be configured using two methods.
You may configure it:
•
Through the web-based management utility
•
Directly through a command line interface (using a SSH or a telnet or a serial console)
The management utility accesses the switch module through any web browser. To access
the switch directly, use the command line interface.
Any port may be configured as up (active) or down (inactive). All ports are active by default.
Chapter 3: Installation and Setup