WEG WECM-AL80-85A2 Installation, Operation And Maintenance Manual page 13

Table of Contents

Advertisement

Notes:
a.
The DC voltage signal can be applied by an external power supply or using the built-in
10VDC source and an additional potentiometer (5kΩ to 10kΩ);
b. Maximum speed adjusted (see item 6.3);
c.
Solution minimum speed (lowest value of the speed range);
d. Input signal (V DC, mA DC, %) supplied to the respective remote input.
Control cable electrical connections diagram:
Figure 7 - DC voltage input
(using built-in power supply)
Figure 9 - DC current input
Recommendation for maximum conductors' length to avoid signal drop for each connection type.
Signal Type
DC voltage
(built-in power supply)
DC voltage
(external power supply)
DC current
Frequency
Modbus (optional)
ATTENTION!
The built-in power supply has an output limit of 25mW or 2,5mA;
g
The product can be permanently damaged if imposed signals out of the specifi-
g
cation;
Make sure that all unused conductors in control cable are insulated to avoid prod-
g
uct malfunction or damage.
The connection between the Yellow cable (10VDC power source) and the red
g
cable (DC current) will damage permanently the DC current speed control.
Conductors
Yellow
Blue
Blue
Red
Brown
Yellow
Red
Table 7 - Maximum conductors' length recomended for signal wires
Figure 8 - DC voltage input
(using external power supply)
Figure 10 - Frequency input
Maximum Length (m)
Black
150 m
Blue
150 m
Blue
150 m
Blue
150 m
Black
150 m
www.weg.net
Cable specification
24 AWG
24 AWG
24 AWG
24 AWG
24 AWG
WECM / Emerald eZA Manual | 13