Axis number setting

Set the axis number between 0 to F using the axis number switch (refer to
The setting is applied at the next power-on or inverter reset.
Set the switch marked with an arrow ( ) to the axis number (0-9, A-F) corresponding to the desired axis.
Axis number
Definition
0 (initial status)
1st axis
1
2nd axis
2
3rd axis
3
4th axis
4
5th axis
5
6th axis
6
7th axis
7
8th axis
NOTE
• Do not change the axis number while the inverter power is ON. Otherwise you may get an electric shock.
• Set the axis number switch with precision so that the arrow on the switch points just a number or letter position. If the switch
is set between numbers, normal data communication cannot be made.
• You cannot set the same axis number to other devices on the network. (Doing so disables proper communication.)
28
INSTALLATION
Axis number
Definition
8
9th axis
9
10th axis
A
11th axis
B
12th axis
C
13th axis
D
14th axis
E
15th axis
F
16th axis