Switch setting and display of the servo amplifier

Network settings can be configured using switches on the servo amplifier. The network communication status and alarm
status can also be checked on the display (1-digit, 7-segment LED) of the servo amplifier.

Switches

If a metal screw driver contacts with the conductive areas, the switches may malfunction. Therefore, use an insulated screw
driver instead of a metal screw driver to operate the rotary switches (SW1/SW2).
To apply the settings of all switches, cycle the power supply or reset the software.
The following explains the rotary switches (SW1/SW2).
Switch identification
1-digit, 7-segment LED
Rotary switches (upper digit)
(SW1)
Rotary switches (lower digit)
(SW2)
Rotary switches (SW1/SW2)
The IP address can be set with the rotary switches (SW1/SW2) of the servo amplifier. SW1 indicates an upper digit and SW2
indicates a lower digit of a hexadecimal.
To set the address to 02h, set the rotary switches to the following positions.
The rotary switches are set to 01h when shipped from the factory.
To apply the settings of the rotary switches, set "0" (the rotary switch is used.) in [Pr. NPA01 IP address setting]. To set the IP
address without using the rotary switches, set them to 0 and use an engineering tool.
For how to set IP addresses, refer to "IP address setting function" in the following manual.
MR-JET-G User's Manual (Communication Function)