Receiving; Unpacking; Selecting A Location - lancer S8H Installation, Operation & Service Manual

Hi-carb superchiller
Table of Contents

Advertisement

S8H Hi-Carb Superchiller 230V / 50Hz
3.1

Receiving

Each unit is completely tested under operating conditions and thoroughly inspected before
shipment. At time of shipment, the carrier accepts the unit and any claim for damage(s) must
be made with the carrier. Upon receiving units from the delivering carrier, carefully inspect
shipping crate for visible indication(s) of damage. If damage exists, have carrier note damage
on bill of lading and file a claim with the carrier.
3.2

Unpacking

Carefully unpack the Lancer S8H Superchiller from the shipping carton, remove the wooden
base.
3.3

Selecting a Location

The S8H Superchiller should be located in a well-ventilated, firm, level location close to
dispenser, water and electrical supplies, with easy access for servicing
Ensure sufficient clearance around Superchiller to allow good fresh air circulation through
the condenser – allow at least 200mm at rear and sides.
www.lancerbeverage.com
Hoshizaki Lancer reserve the right to change specifications without notice.
Images are for illustration purposes only as product may vary.
The use of gloves is recommended to protect hands from potential injury
Caution
from sharp edges. The Superchiller must always be handled in a horizontal
position.
Superchillers are intended for indoor operation only; do not operate outside
unless suitably protected by a weatherproof enclosure.
Warning
This appliance is not suitable for installation in an area where a water jet could
be used. Superchilllers are not to be installed in a kitchen.
When positioning the appliance, ensure the supply cord is not trapped or
damaged.
Warning
Do not locate multiple portable socket-outlets or portable power supplies at
the rear of the appliance.
The Superchiller is not suitable for use in subfreezing temperatures.
Caution
To prevent damage to the water supply line, turn off and drain unit when air
temperature is below zero.
The Superchiller is only to be installed in locations where its use and
Caution
maintenance is restricted to trained personnel.
The Superchiller must not be confined to an area less than 18m
Warning
ventilation.
To install the castors, lift the chiller with
appropriate help and screw the castors into the
mounting plates provided. DO NOT tilt the
chiller more than 45 degrees or lay chiller on
its side.
3
and without
Page 7 of 28
Part No: 68000036
No. 111 – 4 Apr 22