lancer Siberian Elite Series Installation, Operation & Service Manual

Glycol chiller 220v / 60hz

Advertisement

Quick Links

Siberian™ Elite Glycol Chiller
220V / 60Hz
Installation, Operation &
Service Manual
www.lancerbeverage.com

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Siberian Elite Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for lancer Siberian Elite Series

  • Page 1 Siberian™ Elite Glycol Chiller 220V / 60Hz Installation, Operation & Service Manual www.lancerbeverage.com...
  • Page 2: Table Of Contents

    Certificate of Warranty ....................... 16 Manufacturer’s Checklist ....................17 www.lancerbeverage.com Page 2 of 17 Hoshizaki Lancer reserve the right to change specifications without notice Part No: 68000205 No 016 – 12 February 2016 Images are for illustration purposes only as product may vary.
  • Page 3: Introduction

    2. The Company Hoshizaki Lancer is a wholly owned subsidiary of Lancer Corporation, a world leader in the supply of Beverage Dispensing Equipment based in San Antonio, Texas. Lancer has manufacturing bases and distribution networks in 97 countries.
  • Page 4: Product Details

    Siberian Elite Glycol Chiller 220V / 60Hz 4. Product Details 4.1 Product Features The Hoshizaki Lancer Siberian™ system chiller is supplied with the following features as standard:  Rotationally moulded inner & outer polypropylene tank offering long life and corrosion resistance ...
  • Page 5: Options

     Unit is for indoor use only unless suitably protected by a weatherproof enclosure.  The Hoshizaki Lancer Siberian™ system chiller should be located in a well-ventilated area that will allow easy access for servicing.  Install on a flat, level surface. Level adjustments can be made on the adjustable legs. (Option) ...
  • Page 6: Refrigeration Connection

    Pollution of the liquid could occur due to leakage of lubricants (for submersible pumps and vertical wet pit pumps containing lubricants) 5.5 Connecting Glycol Lines  Connect glycol lines from the manifolds to the Hoshizaki Lancer Siberian™ system chiller.  Supply manifold direct to pump(s). ...
  • Page 7: Filling Unit With Glycol / Water

    HEAT EXCHANGER AND REFRIGERATION SYSTEM, AND WILL VOID ALL WARRANTY The Hoshizaki Lancer Siberian™ system chiller requires a 30% glycol / water mixture. Put 12.7 gallons of glycol in the tank and fill with water until the glycol / water mixture reaches the overflow.
  • Page 8 2. The Thermostat will not be energised unless the refrigeration control switch is turned on. www.lancerbeverage.com Page 8 of 17 Hoshizaki Lancer reserve the right to change specifications without notice Part No: 68000205 No 016 – 12 February 2016 Images are for illustration purposes only as product may vary.
  • Page 9: Thermostat- Carell Pjexs - Thermostat Parameters

    All other non used parameters are hidden to avoid confusion. www.lancerbeverage.com Page 9 of 17 Hoshizaki Lancer reserve the right to change specifications without notice Part No: 68000205 No 016 – 12 February 2016 Images are for illustration purposes only as product may vary.
  • Page 10: Programming Instructions

    Antifreeze alarm can be reset by holding “UP” and “DOWN” keys for 5 seconds. www.lancerbeverage.com Page 10 of 17 Hoshizaki Lancer reserve the right to change specifications without notice Part No: 68000205 No 016 – 12 February 2016 Images are for illustration purposes only as product may vary.
  • Page 11: Scheduled Maintenance

    -4°F -22°F glycol / water mix www.lancerbeverage.com Page 11 of 17 Hoshizaki Lancer reserve the right to change specifications without notice Part No: 68000205 No 016 – 12 February 2016 Images are for illustration purposes only as product may vary.
  • Page 12: Trouble Shooting

    System leak Low glycol % Add glycol www.lancerbeverage.com Page 12 of 17 Hoshizaki Lancer reserve the right to change specifications without notice Part No: 68000205 No 016 – 12 February 2016 Images are for illustration purposes only as product may vary.
  • Page 13: Electrical Diagram - Carel Thermostat

    9. Electrical Diagram – Carel Thermostat www.lancerbeverage.com Page 13 of 17 Hoshizaki Lancer reserve the right to change specifications without notice Part No: 68000205 No 016 – 12 February 2016 Images are for illustration purposes only as product may vary.
  • Page 14: Wiring Diagram - Carel Thermostat

    10. Wiring Diagram – Carel Thermostat www.lancerbeverage.com Page 14 of 17 Hoshizaki Lancer reserve the right to change specifications without notice Part No: 68000205 No 016 – 12 February 2016 Images are for illustration purposes only as product may vary.
  • Page 15: Spare Parts List

    PUMP INSULATOR SPK 220 60 85000100 LID SIBERIAN INSPECTION USA www.lancerbeverage.com Page 15 of 17 Hoshizaki Lancer reserve the right to change specifications without notice Part No: 68000205 No 016 – 12 February 2016 Images are for illustration purposes only as product may vary.
  • Page 16: Certificate Of Warranty

    Parts and Equipment Hoshizaki Lancer provides a warranty period of twelve (12) months from the date of original invoice for all manufactured parts and the associated labour. Repair or replace of defective parts will be at the sole discretion of Hoshizaki Lancer.
  • Page 17: Manufacturer's Checklist

    Work Order No: ................Affix label here www.lancerbeverage.com Page 17 of 17 Hoshizaki Lancer reserve the right to change specifications without notice Part No: 68000205 No 016 – 12 February 2016 Images are for illustration purposes only as product may vary.