S8H Hi-Carb Superchiller 230V / 50Hz
3.6

Plumbing the drain and CO2 Exhaust.

The waterbath drain / overflow tube should be plumbed to a suitable drain, installation in
accordance with the Plumbing Code of Australia and AS/NZS 3500.1 and AS/NZS 3500.2.
The 6mm tube labelled as CO2 EXHAUST should be plumbed to a well-ventilated safe outside
area.
3.7

Connecting to CO2 supply

Connect CO2 supply line from regulator to each CO2 IN line on the chiller. There may be 2
lines to connect for 5 pump models.
Adjust CO2 Regulator supplying Carbonator to 550 kpa.
Turn on CO2 supply and check all connections for leaks. Repair any leaks before
continuing.
3.8

Filling the waterbath

Check that the Superchiller is unplugged from the mains electrical supply
Remove the top panel.
Fill the water tank with water up to the 'FILL LEVEL' marked on the inside of the tank.
Refit the top panel
NOTE: Proper icebank control function depends on the conductivity of the water used. The
Electrical Conductivity should be between 100 and 300 uS/cm. Below 100 uS/cm the compressor
may not work properly, above 300 uS/cm the lines may freeze.
3.9

Electrical Connection

It is recommended that the Superchiller is connected to a separate 230VAC 50Hz 15 Amp
electrical supply, protected by an appropriate circuit breaker and Residual Current Device.
Check the nameplate on the Superchiller for the electrical supply requirements.
The service of a licensed electrician may be required to ensure the installation is in
accordance with the local codes and regulations.
www.lancerbeverage.com
Hoshizaki Lancer reserve the right to change specifications without notice.
Images are for illustration purposes only as product may vary.
As carbon dioxide (CO
Warning
paramount. If a leak is suspected, immediately ventilate the
contaminated area, before attempting repairs.
Disconnect the power before opening the top cover for filling the water
bath.
Warning
When filling the water tank, care must be taken to not splash water onto
the electrical components
To prevent possible electrical shock or extensive damage to the unit, the
appliance must be connected with the flexible cord supplied with the
Warning
appliance to an appropriate electrical outlet socket installed in
accordance with local codes and regulations i.e. AS/NZS 3000.
If the supply cord is damaged, it must be replaced by the manufacturer,
Warning
its service agent or similarly qualified persons with a replacement cord
available from Hoshizaki Parts/Service Centres.
) displaces oxygen; prevention of CO
2
leaks is
2
Page 10 of 28
Part No: 68000036
No. 111 – 4 Apr 22