Pre-Installation Inspection - Emerson Rosemount 3410 Series Reference Manual

Gas ultrasonic flow meters
Hide thumbs Also See for Rosemount 3410 Series:
Table of Contents

Advertisement

Reference Manual
00825-0200-3104
 CAUTION
FAULTY METER INSTALLATION
Correctly install the equipment.
If meter bodies are mounted or oriented differently than specified above, debris or gas
may collect in the transducer ports which could adversely affect the transducer signals, or
cause equipment damage.
Normally, the meter body is installed so that the electronics assembly is on the top
of the meter. If there is insufficient space above the piping for this arrangement, the
meter can be ordered with extra long transducer cables for remote mounting or the
meter housing can be installed with the electronics assembly on the bottom.
The mating piping should include temperature measurement connections located a
minimum of three nominal pipe diameters length down stream of the meter, or per
AGA Report No. 9.
2.4 

Pre-installation inspection

Upon receipt of the meter and before installation inspect meter for signs of components
loosening, seal damage or other component damage. This includes:
Procedure
1. Ensure flange sealing faces are undamaged.
2. Movement of components that should be rigid.
2.4.1 
Meter safety for hoist rings and lifting slings
A Rosemount
of a meter run for installation or service by obeying the following instructions.
 DANGER
LIFTING A ROSEMOUNT ULTRASONIC METER WITH OTHER EQUIPMENT
The following lifting instructions are for installation and removal of the Rosemount
Ultrasonic Meter ONLY.
The instructions below do not address lifting the Rosemount ultrasonic meter while it is
attached, bolted, or welded to meter tubes, piping, or other fittings.
Using these instructions to maneuver the Rosemount Ultrasonic Meter while it is still
attached, bolted, or welded to a meter tube, piping, or other fitting can result in death,
serious injury, or equipment damage.
The operator must refer to their company's hoisting and rigging standards, or the "DOE-
STD-1090-2004 Hoisting and Rigging" standard if such company standards do not exist, for
lifting and maneuvering any assembled meter tube and associated piping.
Rosemount 3415, 3416 and 3417 GUSM
If any damage is found, contact Emerson Flow services before putting meter into
service. Refer to the Emerson Flow services contact information on the back cover of
this manual.
Gas Ultrasonic Flow Meter can be safely lifted and maneuvered into and out
Mechanical installation
January 2023
37