Huawei SUN2000-4.95KTL-JPL1 User Manual page 86

Hide thumbs Also See for SUN2000-4.95KTL-JPL1:
Table of Contents

Advertisement

SUN2000-4.95KTL-JPL1
User Manual
Alarm
Alarm Name
ID
2039
Output
Overcurrent
2040
Output DC
Component
Overhigh
2051
Abnormal
Residual
Current
Issue 05 (2023-02-17)
Alarm
Possible Causes
Severity
Major
Cause ID = 1
The power grid voltage
drops dramatically or the
power grid is short-
circuited. As a result, the
SUN2000 transient output
current exceeds the upper
threshold and therefore the
SUN2000 protection is
triggered.
Major
Cause ID = 1
The DC component of the
SUN2000 output current
exceeds the specified upper
threshold.
Major
Cause ID = 1
The insulation impedance
of the input side to PE
decreases when the
SUN2000 is operating.
Copyright © Huawei Technologies Co., Ltd.
8 Maintenance
Troubleshooting
1. The SUN2000 detects its
external working
conditions in real time.
After the fault is
rectified, the SUN2000
automatically recovers.
2. If the alarm occurs
frequently and affects
the energy yield of the
power plant, check
whether the output is
short-circuited. If the
alarm persists, contact
your dealer or Huawei
technical support.
1. The SUN2000 detects its
external working
conditions in real time.
After the fault is
rectified, the SUN2000
automatically recovers.
2. If the alarm occurs
frequently, contact your
dealer or Huawei
technical support.
1. If the alarm occurs
occasionally, the
external circuit may be
abnormal temporarily.
The SUN2000
automatically recovers
after the fault is
rectified.
2. If the alarm occurs
frequently or persists,
check whether the
impedance between the
PV string and the
ground is too low.
80