  • Page 1 Installation Manual Impaq S / Impaq SC & Impaq S Grade INS877-4...
  • Page 2 • Changed details for sensitivity settings description and tables inline with PCR01407 10-03-2022 • PCR01350 updated PCB schematics and wiring details to accommodate PCB changes. 18-10-2022 • Impaq S Grade 3 added to the manual.
  • Page 3: Table Of Contents

    ........................2.0 Mounting ..........................2.1 Device mounting ....................... 2.2 Magnet mounting (type SC only) ..................3.0 Impaq S and S Grade 3 wiring configuration ..............4.0 Impaq SC wiring configuration ................... 5.0 LED functionality ........................6.0 Setting the shock sensitivity ....................
  • Page 4: Introduction

    1.0 Introduction The Impaq S is a Grade 2 wired shock sensor, the Impaq SC is a Grade 2 wired shock sensor with the option for a magnetic contact, and the Impaq S Grade 3 is a Grade 3 shock sensor.
  • Page 5 INS877-4 5/26...
  • Page 6: Impaq Sc

    Icon Item LED function select DIP switch Sensitivity selection button Alarm resistance value selection DIP switch Tamper resistance value selection DIP switch Input terminal block 1.2 Impaq SC INS877-4 6/26...
  • Page 7 INS877-4 7/26...
  • Page 8 Icon Item LED function select DIP switch Sensitivity selection button Magnet sensor Alarm resistance value selection DIP switch Tamper resistance value selection DIP switch Input terminal block 1.3 Impaq S Grade 3 INS877-4 8/26...
  • Page 9 INS877-4 9/26...
  • Page 10: Mounting

    Screw Diameter 2.9-3.2mm Screw length: 15.8-24.5mm Impaq S Grade 3 MUST use the fixing points shown in RED on Fig 3 for the removal from mounting tamper to function correctly. Care should be taken when screwing through the PCB for the rear tamper breakout.
  • Page 11 the magnet. Figure 1 INS877-4 11/26...
  • Page 12 Figure 2 Figure 3 INS877-4 12/26...
  • Page 13: Magnet Mounting (Type Sc Only)

    2.2 Magnet mounting (type SC only) Once the device has been mounted, position the magnet so the notch is aligned with the arrow marker on the PCB. The magnet can be installed on either side of the device. Greater sensitivity is achieved by positioning the magnet so the notch is aligned with the arrow (see figure 4 for magnet distances).
  • Page 14 Approach Min Removal Max Axis (mm) (mm) Right INS877-4 14/26...
  • Page 15 Left Once the correct position has been located fix the magnet in place (see figure 5) Figure 5 INS877-4 15/26...
  • Page 16: Impaq S And S Grade 3 Wiring Configuration

    3.0 Impaq S and S Grade 3 wiring INS877-4 16/26...
  • Page 17 The Impaq S and S Grade 3 have three wiring options. In all cases, power should be provided to the 0V and 12V by an EN50131 compliant power supply. Option 1 The alarm and tamper loops can be wired independently and function as normally closed zone inputs.
  • Page 18 Note: the EOL DIP switches should all be turned OFF in this configuration Option 3 The third way of wiring an Impaq S is to use the EOL DIP switch selected resistors for alarm and tamper. In this configuration. The zone wires should then be connected to the outer alarm and tamper terminals.
  • Page 19 Select the correct resistance value for Tamper and Alarm by moving the DIP switch to the ON position (Texecom values shown in example below). EOL DIP Switch Position Tamper Alarm Manufacturer Texecom Honeywell Scantronic/Menvier INS877-4 19/26...
  • Page 20: Impaq Sc Wiring Configuration

    NOTE: The product will only function if both DIP switches have a single switch set to the ON position. If multiple switches are moved, the product will not function as expected. Optional wiring There is a facility to remotely enable the walk test LED from the panel. To use this connect a wire from the RLED terminal to an output of the panel.
  • Page 21 Select the correct resistance value for Tamper and Alarm by moving the DIP switch to the ON position (Texecom values shown in example below). EOL DIP Switch Position Tamper Alarm Manufacturer Texecom Honeywell Scantronic/Menvier INS877-4 21/26...
  • Page 22: Led Functionality

    NOTE: The product will only function if both DIP switches have a single switch set to the ON position. If no switches or multiple switches are moved, the product will not function as expected. Optional wiring There is a facility to remotely enable the walk test LED from the panel. To use this, connect a wire from the RLED terminal to an output of the panel.
  • Page 23: Setting The Shock Sensitivity

    6.0 Setting the shock sensitivity After powering up the device, single press the sensitivity button and the LED will flash blue defaulting to sensitivity setting 2. There are 5 sensitivity settings from 1 to 5 with 1 being the least sensitive (slowest flash rate) and 5 the most sensitive.
  • Page 24: Specifications

    Note: To be used with PSU’s that have a current limit of 5A or below. Note: Product is designed for indoor use only. Specifications EN50131-2-8:2017, EN50131-2-6:2008 (Impaq SC only) Alarm System EN50131-1:2006+A2:2017, Impaq S & SC PD6662:2017, Grade 2 Class II EN50131-2-8:2017 Alarm System Impaq S EN50131-1:2006+A2:2017, Grade 3...
  • Page 25: Legal Information

    Maintenance: Test yearly by the installer. Warranty: 2 year replacement warranty. As the Impaq S/SC and Impaq S Grade 3 is not a complete alarm system, but only a part thereof, Texecom cannot accept responsibility or liability for any damages whatsoever based on a claim that the Impaq S/SC and Impaq S Grade 3 failed to function correctly.
  • Page 26 Hereby, Texecom declares that the equipment type : AEJA0000 (Impaq S), AEKA0000 (Impaq SC), and AELA0000 (Impaq S Grade 3) are in compliance with the Electo-magnetic Compatibility (EMC) Directive 2014/30/EU. The full EU declaration of conformity is available here: Impaq...