BayStream 7.3 Documentation Change Notice
Figure 7.
Displaying the Interfaces
Figure 8.
Enabling Statistics Collection for an Interface
TI set command
[4:1] $ set wfFrSwDlcmiEntry.4.wfFrSwDlcmiSvcStatsEnable 2; commit
Statistics Data Collection File
BayStream Statistical Data Collection software gathers, aggregates, and reports
on three types of records for ATM lines:
•
Interface card or slot (the equivalent of one OC-3 line)
•
ATM PVCs configured for a slot
•
Each virtual channel (VCL statistics) pertaining to an ATM-configured slot
VCL statistics are new for BayStream Version 7.3. To support VCL statistics
collection in Site Manager, the ATMizer VCL Bit Mask parameter has been
added.
28
TI list command
[4:1] $ list -i wfFrSwDlcmiEntry
instances (show all instances of wfFrSwDlcmiEntry)
circuit number
DLCMI MIB Entry
BayStream Multiservice Software Version 7.3
DLCMI MIB Entry
BYS0094A
attribute identifier
attribute value (1=disable; 2= enable)
BYS0095A
115385-D Rev 01