Command
Description
CHG ZONE <zoneNumber> <intraZoneBandwidth> <intraZoneStrategy>
<interZoneBandwidth> <interZoneStrategy> [<zoneIntent> <zoneResourceType>]
Change the parameters of an existing zone, where:
In CS 1000 Release 5.0 , the zones that were described with BMG designator
stay with BMG one, all the other zones are provided with MO designator. It is
possible to update ZoneIntent using the CHG ZONE command.
CHG ZQRT <Zone> <Incr>
Change ZQRT, which is Response time increase by percentage. It is used to
determine the increase to the Sliding Maximum for the identified zone, where:
CHG ZQRTI <Zone> <Interval>
Copyright © 2005-2007, Nortel Networks
.
zoneNumber = 1-255
intraZoneBandwidth = 1000000 (Mbit/s)
intraZoneStrategy = intrazone preferred strategy
— Best Quality = BQ
— Best Bandwidth = BB
interZoneBandwidth = 1000000 (Mbit/s)
interZoneStrategy = intrazone preferred strategy
— Best Quality = BQ
— Best Bandwidth = BB
zoneIntent = type of zone, where:
— MO = Main Office zone
— BMG = Branch Media Gateway (branch office) zone
— VTRK = Virtual Trunk zone
zoneResourceType = resource intrazone preferred strategy
— shared DSP channels (default) = shared
— private DSP channels = private
Zone = 1-255
Incr = increase value in percentage = 1-(10)-100
Nortel Communication Server 1000
Main Office Configuration Guide for SRG 50
NN43001-307 02.02 Standard
Release 5.0 3 December 2007