Hantek 6022BE User Manual
Hide thumbs Also See for 6022BE:

Advertisement

Quick Links

Hantek
USER'S
MANUAL
6022BE
The User's Manual

Advertisement

Table of Contents
loading

Summary of Contents for Hantek 6022BE

  • Page 1 Hantek USER’S MANUAL 6022BE The User’s Manual...
  • Page 2: Table Of Contents

    Hantek Electronic co.,Ltd. No.177 zhuzhou road(huite industry city), QingDao,China www.hantek.com Content General Safety Summary ................1 Chapter 1 Getting Start ................... 2 System Requirement ........................3 Install Software ........................... 4 Install Driver ..........................7 General Features ........................10 Function Check ......................... 10 Probe Compensation .........................
  • Page 3 The Utility Function ........................43 The display System ........................46 Save and Load ........................... 50 Print ............................51 Chapter 4 Application Example ..............52 Simple Measurement ........................ 53 Capturing a Single-Shot Signal ....................54 The Application of the X-Y Operation ..................55 Taking Cursor Measurements ....................
  • Page 4: General Safety Summary

    Hantek 6022BE General Safety Summary Review the following safety precautions carefully before operate the device to avoid any personal injuries or damages to the device and any products connected to it. To avoid potential hazards use the device as specified by this user’s guide only.
  • Page 5: Chapter 1 Getting Start

    Hantek 6022BE Chapter 1 Getting Start The oscilloscope is small, lightweight, no external power required, portable oscilloscopes! The oscilloscopes is ideal for production test, research and design and all of the applications involving analog circuits test and troubleshooting, as well as education and training.
  • Page 6: System Requirement

    Hantek 6022BE System Requirement To run the oscilloscope software, the needs of computer configuration are as follows: Minimum System Requirements Operating System Window 2000/XP/VISTA/7 Processor Upwards of 1.00G processor Memory 128M byte Disk Space 500M disk free space Screen resolution...
  • Page 7: Install Software

    Hantek 6022BE Install Software Caution: You must install the software before using the oscilloscope. 1. While in Windows, insert the installation CD into the CD-ROM drive. 2. The installation should start up automatically. Otherwise in Windows Explorer, switch to the CD-ROM drive and run Setup.exe.
  • Page 8 Hantek 6022BE 5. Check the setup information. Click Next to start copying of files. 6. This Status dialog is displayed during copying of files. The User’s Manual...
  • Page 9 Hantek 6022BE 7. Updating Your System Configuration. 8. The installation is complete. The User’s Manual...
  • Page 10: Install Driver

    Hantek 6022BE Install Driver Connect the A-Type Plug of USB cable to your PC’S USB port. Connect the B-Type Plug of USB cable to Hantek 6022BE’S USB port. New hardware is found. 4.New hardware search wizard starts. The User’s Manual...
  • Page 11 Hantek 6022BE 5.New hardware search wizard starts to search the driver. 6.New hardware wizard installs “Hantek 6022BE DRIVER ”. The User’s Manual...
  • Page 12 Hantek 6022BE 7.The wizard has finished installing for “Hantek 6022BE DRIVER ”. The User’s Manual...
  • Page 13: General Features

    Hantek 6022BE General Features Product features:  Dual Channel, Bandwidth: 48MSa/s  Maximum real-time sample rate: 1Mbytle/channel  Automatic setup for ease of use (AUTOSET);  20 Automatic measurements;  Automatic cursor tracking measurements;  waveform storage;  User selectable fast offset calibration;...
  • Page 14 Hantek 6022BE  Input a signal to a channel of the oscilloscope The oscilloscope is equipped with dual channels plus external trigger. Please input signal in the following steps: 1. Set the attenuation switch on the probe as 10X and connect the probe on the oscilloscope with CH1.
  • Page 15: Probe Compensation

    Hantek 6022BE Probe Compensation Perform this function to match the characteristics of the probe and the channel input. This should be performed whenever attaching a probe to any input channel at the first time. ■ From the “Probe” menu, select attenuation to 1:10. Set the switch to “X10” on the probe and connect it to CH1 of the oscilloscope.
  • Page 16: Self Calibration

    Hantek 6022BE Under Compensated ■ If necessary, use a non-metallic tool to adjust the trimmer capacitor of the probe for the fattest square wave being displayed on the oscilloscope. ■ Repeat if necessary. WARNNING: To avoid electric shock while using the probe, be sure the perfection of the insulated cable, and do not touch the metallic portions of the probe head while it is connected with a voltage source.
  • Page 17: Chapter 2 Operating Basics

    Hantek 6022BE Chapter 2 Operating Basics  The User’s Interface  The Menu System  The Vertical System  The Horizontal System  The Trigger System The User’s Manual...
  • Page 18: The User's Interface

    Hantek 6022BE The User’s Interface Click the software icon on the desk after you finished the software setting and equipment connecting. Then a user interface will be showed as follows: In addition to displaying waveforms, the display area is filled with many details about the waveform and the oscilloscope control settings.
  • Page 19 Hantek 6022BE 3. Control Panel 4. The Horizontal Panel The user can change Time/Div, format in the panel. 5. The Vertical Panel The user can turn on/off the CH1/CH2. Also the user can change the CH1/CH2 volt/div, coupling and probe attenuation.
  • Page 20: The Menu System

    Hantek 6022BE The Menu System The Main Menu File: Load or Save data, setup View: Change the user interface The User’s Manual...
  • Page 21: The Vertical System

    Hantek 6022BE Cursor: Cursor measure setup Display: The waveform display setup Utility: Utility setting Help: Turn on help file The Vertical System The following figure shows the vertical system menu. It shows the vertical parameters setting. The User’s Manual...
  • Page 22: The Horizontal System

    Hantek 6022BE CH1: Leads to the setting of the CH1 parameters CH2: Leads to the setting of the CH2 parameters Use the left mouse button to dragging the channel icon to set the vertical position offset precisely. Invert: The invert function turns the displayed waveform 180 degrees.
  • Page 23: The Trigger System

    Hantek 6022BE The Trigger System The following figure shows the trigger system control. Mode: Sets the trigger mode to Edge trigger Sweep: Selects the trigger sweep mode to AUTO, NORMAL or SINGLE Source: Selects the trigger source to CH1, CH2, ALT, EXT or EXT/10...
  • Page 24: Input Connectors

    Hantek 6022BE Input Connectors CH 1/CH 2: Input connectors for waveform display. EXT.: Input connector for an external trigger source. Use the Trigger Menu to select the Ext. or Ext./10 trigger source. Other Connector: GND.: a ground terminal USB PORT: Connect the B-Type Plug of USB cable to this port.
  • Page 25: Chapter 3 Understanding Function

    Hantek 6022BE Chapter 3 Understanding Function  Set Oscilloscope  Set Vertical System  Set Horizontal System  Set Trigger System  Utility Function  Measure Signal  Utility Function  Save and Load  Print The User’s Manual...
  • Page 26: Set Oscilloscope

    Hantek 6022BE Set Oscilloscope Save Setup The oscilloscope software saves the current setup before you close the oscilloscope software. The oscilloscope recalls this setup the next time you run the software. You can use the “Save Setup” menu to permanently save up to several different setups.
  • Page 27 Hantek 6022BE The Vertical Menu function: Turn ON/Off: Turn on/off the channel  Volt/DIV: Select the channel voltage/div  Coupling: Select the channel coupling  Probe: Select the channel probe attenuation   Change Volt/DIV You can click “Volt/Div” in “CH1/CH2” Menu to select the voltage You can also change “CH1/CH2”...
  • Page 28 Hantek 6022BE  Set Channel Coupling Click “Coupling” in “Channel” menu In the sidebar, you can change the channel coupling too. You can set the coupling to DC, AC or GND. If you set the coupling to DC, it blocks the AC component of the input signal.
  • Page 29 Hantek 6022BE Turn off invert Turn on invert The following picture shows the waveform before inversion: The User’s Manual...
  • Page 30 Hantek 6022BE The following picture shows the waveform of inversion: Set Math Click in Toolbar. The MATH Menu: The User’s Manual...
  • Page 31 Hantek 6022BE Turn On/Off: Turn On/Off the MATH Channel.  Source A/B: Set the sources of the math channel.  The mathematic functions include addition, subtract, multiply and division for CH1 and CH2. In this function, use the addition, subtraction, multiplication,division function and FFT to operate and analyze the waveform.
  • Page 32 Hantek 6022BE Fast Fourier Transform Function You can use the FFT mode to convert a time-domain signal into its frequency components (spectrum). You can use the FFT mode for the following types of analysis:  Measure harmonic content and distortion in systems ...
  • Page 33 Hantek 6022BE You can select the Source channel, Window algorithm, FFT number, and FFT Zoom factor. It displays only one FFT spectrum at a time. Source: Selects the channel used as the FFT source Window: Selects the FFT window type...
  • Page 34 Hantek 6022BE Harmonic information window shows the information of Harmonics. Measurement information window shows the information about measurement of FFT. Measurement Parameters: : Amplitude of the fundamental frequency : Sum of Amplitude of Harmornic (excluding fundamental frequency) : Sum of Noise (excluding fundamental frequency, Harmonics, DC and...
  • Page 35 Hantek 6022BE : Total Number of bins of Noise. SNR (Signal to Noise Ratio): The ratio of the amplitude of the fundamental frequency to the Noise. ENOB (Effective Number of Bits) : The number of bits in an ideal converter that would be required to give the same SNR performance.
  • Page 36 Hantek 6022BE <![endif]> The FFT display Windows: Set referance Click in Toolbar to set REF channel. The User’s Manual...
  • Page 37: Set Horizontal System

    Hantek 6022BE The Reference Channel Function: Turn On/Off: Turn on/off the reference channel.  Volt/DIV: Channel the resolution of the reference channel.  Reset: Reset the reference channel vertical position to zero.  The Reference Waveform Display Window: Note: If you turn on the “Reference” channel, the load file window will appear.
  • Page 38: Set Trigger System

    Hantek 6022BE Format: leads the setting of the horizontal format parameters The time base ranges of the oscilloscope is listed as follows. The horizontal scan speed is from 4ns/div to 1hour/div. In the “Format” menu of the “Horizontal” menu, select the display mode to Y- T, X-Y .
  • Page 39 Hantek 6022BE on the rising or the falling edge of a signal. Select Edge trigger mode to trigger on Rising edge or Falling edge. Mode: Select the trigger mode. The oscilloscope only provides edge trigger mode. Sweep: Set the sweep mode to Auto, Normal or Single.
  • Page 40: Measure Signal

    Hantek 6022BE Measure Signal  Cursor  Measure Cursor Menu Click “Cursor” in main menu This method allows you to take measurements by moving the cursors 1. Source The user can set the source to CH1, CH2, FFT and MATH. But the FFT source can only use Trace type.
  • Page 41 Hantek 6022BE The Cross cursor display window The Cross measure result displays on status bar 2) Vertical The Vertical cursors appear as vertical lines on the display and measure the vertical parameters. The Vertical cursor display window The User’s Manual...
  • Page 42 Hantek 6022BE The Vertical cursor measure result display on status bar 3) Horizontal The Horizontal cursors appear as horizontal lines on the display and measure the horizontal parameters. The Horizontal cursor display window The User’s Manual...
  • Page 43 Hantek 6022BE The Horizontal cursor measure result display on status bar To acquire and display a signal, please do the steps as follows: Connect signal to CH1 by using probe The DSO set the vertical, horizontal, and triggers controls at the best status automatically.
  • Page 44 Hantek 6022BE Measure Select Channel Maximum: Voltage of the absolute maximum level, Measured over the entire waveform Minimum: Voltage of the absolute minimum level, Measured over the entire waveform Peak To Peak: Peak-to-peak = Max – Min, Measured over the entire...
  • Page 45 Hantek 6022BE Preshoot: Positive Overshoot = (Max - Top)/Amp x 100 %, Measured over the entire waveform Overshoot: Negative Overshoot = (Base - Min)/Amp x 100 %, Measured over the entire waveform Period: Time to take for the first signal cycle to complete in the waveform...
  • Page 46: The Utility Function

    Hantek 6022BE The Utility Function Click the “Menu -> Utility” to get into the “Utility” menu. The “Utility” Functions:  Calibrate  Factory Setup  Interpolation Factory Setup Click “Factory Setup” in “Utility” menu to load default setups When you click the Factory Setup in Utility menu, the oscilloscope displays the CH1 and CH2 waveforms and removes all other waveforms.
  • Page 47 Hantek 6022BE Interpolation Click “Utility->Interpolation” The Step Interpolation The Linear Interpolation The User’s Manual...
  • Page 48 Hantek 6022BE The Sin(x)/x Interpolation Note: The default interpolation mode is Sin(x)/x. The User’s Manual...
  • Page 49: The Display System

    Hantek 6022BE The display System Click “Display” in main menu The following figure shows the display system menu. It shows the display parameters setting.  Type  Grid  Intensity Display type Click “Type” in “Display” menu. The following figure shows the type parameters setting.
  • Page 50 Hantek 6022BE If the Dots type mode is selected, the waveform will be displayed as following figure. The User’s Manual...
  • Page 51 Hantek 6022BE Display Grid Click “Display” in main menu The grid shows: The grid not shows: The User’s Manual...
  • Page 52 Hantek 6022BE Display Intensity Click “Display->Intensity” in main menu The following figure shows the intensity dialog. It shows the display parameters setting. You can change the grid and waveform color intensity in this dialog. The User’s Manual...
  • Page 53: Save And Load

    Hantek 6022BE Save and Load Click “File” in main menu to save waveform, setups and screen 1. Save Data The User’s Manual...
  • Page 54: Print

    Hantek 6022BE Save waveform data 2. Save Setups Save the current oscilloscope setups to file Click “File” in main menu to recall saved waveform, setup 1. Load Data Load the waveform 2. Load Setup Load the instrument that had saved Print 1.
  • Page 55: Chapter 4 Application Example

    Hantek 6022BE In ”PrintPreview” window, use the button to change the size of the waveform graph. Click the “Close” button to turn this window off and click the “Print” button to print the report. Chapter 4 Application Example Simple Measurement ...
  • Page 56: Simple Measurement

    Hantek 6022BE Simple Measurement To acquire and display a signal, please do the steps as follows: Connect signal to CH1 by using probe The DSO set the vertical, horizontal, and triggers controls at the best status automatically. Also, you can adjust the controls to meet your measurement to optimize the waveform display.
  • Page 57: Capturing A Single-Shot Signal

    Hantek 6022BE The results of measure display in Information output. Capturing a Single-Shot Signal To capture a single event, it needs to gather some pre-test knowledge of the signal in order to set up the trigger level and slope correctly. For example, if the event is derived from 3.3V COMS logic, a trigger level of 1.2 or higher...
  • Page 58: The Application Of The X-Y Operation

    Hantek 6022BE 2) Set the Trigger Sweep to Single. 3) Set the Trigger Source to CH1. 4) Set the Trigger Slope to “+” which means you select the rising edge. 5) Adjust the Volts/Div and the time base in a proper range for the signal.
  • Page 59 Hantek 6022BE Signal in X-Y Format: Instruction of the Ellipse Method The User’s Manual...
  • Page 60: Taking Cursor Measurements

    Hantek 6022BE Sinθ = A/B or C/D, where θ = phase shift (in degrees) between the two signals. From the formula above: θ = ±arcsine (A/B) or ±arcsine (C/D) θ must be in the range of (0~π/2) or (3π/2~2π) if the main axis of the ellipse is between I and III quadrant, .
  • Page 61 Hantek 6022BE Measure the Frequency and Time: Read the details showing in the status bar. Measure the Amplitude of the First Waveform Peak of the Waveform Do these steps: Click “Cursor->Source”, select CH1 (select CH2 if you want measure CH2).
  • Page 62 Hantek 6022BE Read the details showing in the status bar. Note : Click “Cursor->Type”, select “Cross”, you can measure time and amplitude at one time. The User’s Manual...
  • Page 63: Appendix

    Hantek 6022BE Appendix Appendix A: Specification  Appendix B: General Maintenance  Appendix C: Services and Support  The User’s Manual...
  • Page 64: Appendix A: Specifications

    Hantek 6022BE Appendix A: Specifications Specifications Table: Input Real Real-time sampling:48MS/s Channels 2 Channels 20MHz (-3dB) Bandwidth Vertical resolution 8 bits/channel Gain range 10mV ~ 5V/div @ x1 probe(10mV, 20mV, 50mV, 100mV, 200mV, 500mV, 1V, 2V, 5V/div1,2,5 sequence) 100mV ~ 50V/div @ x10 probe...
  • Page 65: Appendix B: General Maintenance

    Hantek 6022BE Math Measurements Vp-p, Vmax, Vmin, Vmean, Vrms, Vamp, Vtop, Vbase, Vmid,positive overshoot, negative overshoot, cycle mean, cycle RMS, period, frequency, positive pulse width, negative pulse width, rise time (10%~90%), fall time (10%~90%), positive duty cycle, negative duty cycle...
  • Page 66: Appendix C: Services And Support

    Appendix C: Services and Support Thank you for choosing HANTEK. Please contact us through the following ways should you have any inquiry regarding our products. We shall do our best to help you. 1. Contact your local HANTEK distributor;...