Installing The Cable-Management Bracket - IBM Power E1050 Manual

Table of Contents

Advertisement

Review the following animation for a demonstration of how to remove the cassette.
3. Remove the adapter from the cassette.
a) Open the tailstock clamp by rotating the clamp to the right.
b) Open the cassette by pressing and sliding the release bar on the bottom of the cassette to the rear
of the cassette.
c) Remove the adapter by lifting it from the cassette.
Review the following animation for a demonstration of how to remove the adapter from the
cassette.
4. Place the removed adapter on an approved ESD surface.

Installing the cable-management bracket

Install the cable management bracket to provide organization for the cables and cords connecting to the
system.
About this task
To install the cable management bracket, complete the following steps:
Procedure
1. Two cable management bars are included with the system. One bar is wider than the other. The wider
bar is used in racks that have a shorter depth (like the 7014-T42 rack). The shorter bar is used in racks
that have a longer depth (like the 7965-S42 rack). Choose the cable management bar that matches
the depth of the rack that you have.
2. Each cable management bracket takes up three EIA units. Three screws are used to attach each side
of the cable management bracket to the rack flange. Each screw goes in the middle hole of each of the
three EIA rack units. The screws are installed on the inside of the rack flange. Using a sticker or pen,
mark the locations on the inside of the rack flange where the cable management bracket screws will
be installed.
3. Assemble the cable management bracket by attaching the cable management bar to the cable
management brackets, using two M3 screws (D), as shown in Figure 2 on page 8.
4. Attach the cable management bracket to the rack. To attach the cable management bracket to the
rack, complete the following steps:
a. At the rear of the rack, hold one side of the assembled cable management bracket (A) against the
rack flange. Ensure that the bracket aligns with the locations that you marked in step "2" on page 7.
b. From inside of the rack, install three screws (B) through the rack flanges and into the cable
management bracket (A), as shown in Figure 2 on page 8.
c. Repeat this step for the opposite side of the cable management bracket.
5. Adjust the cable management bracket according to your needs by pulling the thumbscrews (C) and
tilting the bracket, as shown in Figure 2 on page 8.
Installing the IBM Power E1050 (9043-MRX)  7