7.8 Procedure for Changing the Timeout Time

Depending on the network camera, the response to the start of live feed may be slow, and as a result, the start of
live feed may fail due to a communication timeout.
In that case, follow the procedure below to extend the timeout time.
■B-32003 Live Feed
(1) Select the script part at the top left of the Live Feed (B-32003) screen.
(2) Select Script Parts Symbol, and then change the value of N0.9001 in the Device and Constant column.
Timeout time: Setting value × 100 (ms)
Default: 200 (Timeout time: 20 seconds)
55/59
GT27/25
SoftGOT
BCN-P5999-1333-2a