82 Procedures for installation of the switch
Attention: In Autonegotiation mode, the Nortel Ethernet Routing Switch
5500 Series automatically provides the proper MDI/MDI-X connection on
the RJ-45 ports; thereby eliminating the need for crossover cables. When
Autonegotiation is disabled on 10/100 ports, they are configured as an
MDI-X connection.
Procedure Steps
Step
1
2
3
4
5
Figure 17
Job aid: Grounding lug location on a 5600 Series switch
Installing transceivers
This procedure describes the steps used to install transceivers.
Copyright © 2008–2009 Nortel Networks
Action
Mount the switch. You can mount a standalone switch on a table
or shelf, the wall, or in a rack.
Connect the ground cable to the switch.
Attach the required cables to the switch.
Install any required transceivers.
Connect the AC power cord.
ERS 5000 Series Installation
NN47200-300 04.03
13 April 2009
--End--