Configuring the nortel 5520-24t-pwr switch supporting power over ethernet with avaya communication manager and avaya ip telephones – issue 1.0 (8 pages)
Page 1
Nortel Ethernet Routing Switch 5500 Series Installation — SFPs and XFPs NN47200-302...
Page 2
While the information in this document is believed to be accurate and reliable, except as otherwise expressly agreed to in writing NORTEL PROVIDES THIS DOCUMENT "AS IS" WITHOUT WARRANTY OR CONDITION OF ANY KIND, EITHER EXPRESS OR IMPLIED. The information and/or products described in this document are subject...
Procedure job aid: SFP models with DDI support 29 Procedure job aid: SFP models with DDI support 30 Installing an SFP 32 Procedure job aid: locking and extractor mechanisms 33 Nortel Ethernet Routing Switch 5500 Series Installation — SFPs and XFPs NN47200-302 01.04 Standard 5.1 27 January 2010...
"1000BASE-LX SFP specifications" (page 45). New document This document is a new document based on Nortel Ethernet Routing Switch 8600 Installation — SFP and XFP Transceivers and GBICs (NN46205-305). Nortel Ethernet Routing Switch 5500 Series Installation — SFPs and XFPs NN47200-302 01.04 Standard...
• GBICs, SFPs, and XFPs use optical connectors whose performance can be reduced by dust contamination. When you store a GBIC, SFP, or Nortel Ethernet Routing Switch 5500 Series Installation — SFPs and XFPs NN47200-302 01.04 Standard 5.1 27 January 2010...
Do not bend the cable to less than a 40 mm radius. • Do not stand on fiber optic cable; keep the cable off the floor. Nortel Ethernet Routing Switch 5500 Series Installation — SFPs and XFPs NN47200-302 01.04 Standard 5.1 27 January 2010...
Compressed air must be free of dust, water and oil, or filmy deposits or scratches on the surface of the connector can result. Nortel Ethernet Routing Switch 5500 Series Installation — SFPs and XFPs NN47200-302 01.04 Standard 5.1 27 January 2010...
Page 15
Gently wipe the cylindrical and end-face surfaces with a dry tissue. Blow dry the connector surfaces with canned air. Nortel Ethernet Routing Switch 5500 Series Installation — SFPs and XFPs NN47200-302 01.04 Standard 5.1 27 January 2010...
This section provides electrostatic discharge (ESD) and installation caution messages. This section provides electrostatic discharge (ESD) and installation caution messages and translations. Nortel Ethernet Routing Switch 5500 Series Installation — SFPs and XFPs NN47200-302 01.04 Standard 5.1 27 January 2010...
Page 18
Riesgo de daño del equipo Para prevenir el daño producido por una descarga electrostática, use siempre una pulsera antiestática conectada a un enchufe ESD. Nortel Ethernet Routing Switch 5500 Series Installation — SFPs and XFPs NN47200-302 01.04 Standard 5.1 27 January 2010...
à vos yeux. Ne regardez jamais en direction de fibres optiques ou d’un port connecteur. Supposez toujours que les câbles de fibres optiques sont connectés à une source de lumière. Nortel Ethernet Routing Switch 5500 Series Installation — SFPs and XFPs NN47200-302 01.04 Standard 5.1 27 January 2010...
Page 21
Never look into an optical fiber or connector port. Always assume that fiber optic cables are connected to a light source. Nortel Ethernet Routing Switch 5500 Series Installation — SFPs and XFPs NN47200-302 01.04 Standard 5.1 27 January 2010...
Use of controls or adjustments, or performance of procedures other than those specified herein can result in hazardous radiation exposure. The products described in this guide meet requirements of: Nortel Ethernet Routing Switch 5500 Series Installation — SFPs and XFPs NN47200-302 01.04 Standard 5.1 27 January 2010...
Page 23
European EN 55 022 statement This is to certify that the Nortel Networks optical routing system is shielded against the generation of radio interference in accordance with the application of Council Directive 89/336/EEC, Article 4a. Conformity is declared by the application of EN 55 022 Class A (CISPR 22).
Page 24
Cet appareil numérique respecte les limites de bruits radioélectriques visant les appareils numériques de classe B prescrites dans le Règlement sur le brouillage radioélectrique du ministère des Communications du Canada. Nortel Ethernet Routing Switch 5500 Series Installation — SFPs and XFPs NN47200-302 01.04 Standard 5.1 27 January 2010...
100 meters (m), 550 m, 10 kilometers (km), 40 km, 70 km, and 120 km. Determine the required media and connector type. Fiber optic cable is required for any reach over 100 m. Nortel Ethernet Routing Switch 5500 Series Installation — SFPs and XFPs NN47200-302 01.04 Standard 5.1 27 January 2010...
—End— Procedure job aid: SFPs and common applications The following table describes the reach provided by various SFPs. This table is informational only—not all Nortel Ethernet switching and routing products support all the SFPs listed here. Table 1 SFPs and common applications...
Procedure job aid: SFP models SFPs are hot-swappable input/output enhancement components designed for use with Nortel products to allow Gigabit Ethernet ports to link with other Gigabit Ethernet ports over various media types. The SFPs described in this section do not have Digital Diagnostic Interface capability, and are RoHS -E5 compliant.
Router 4134 module that supports SFPs. The optical functions of the SFP are supported. Access to the DDI information will be provided in a future release. The following table lists and describes the Nortel SFP models with DDI capability. All these SFPs use LC connectors. Nortel Ethernet Routing Switch 5500 Series Installation —...
SFP are supported. Access to the DDI information will be provided in a future release. The SFPs described in this section are all RoHS -E6 compliant. The following table lists and describes the Nortel SFP models with DDI capability. All these SFPs use LC connectors. Table 6...
A CWDM system uses a grid of wavelengths to provide multiple channels for both ring and point-to-point configurations. All components are color-coded by wavelength. Nortel Ethernet Routing Switch 5500 Series Installation — SFPs and XFPs NN47200-302 01.04 Standard 5.1 27 January 2010...
Page 31
Diagnostics (NN46220-700). For information about DDM, see Nortel Metro Ethernet Routing Switch 8600 Troubleshooting (NN46220-701). The following table lists and describes the Nortel SFP models with DDI capability. All the optical SFPs use LC connectors. Table 8 SFP models with DDI capability...
Figure 1 "SFP with bail lock and extraction mechanism" (page 34), the SFP still has the bore plug installed. Pull the bail to release the device. Nortel Ethernet Routing Switch 5500 Series Installation — SFPs and XFPs NN47200-302 01.04 Standard 5.1 27 January 2010...
Page 34
The following figure shows the wrap-around latch-type extraction mechanism. To remove the device, push the collar towards the module. Figure 3 Wrap-around latch-type extraction mechanism Nortel Ethernet Routing Switch 5500 Series Installation — SFPs and XFPs NN47200-302 01.04 Standard 5.1 27 January 2010...
"1000BASE-BX DDI SFP specifications" (page 51) • "1000BASE-EX DDI SFP specifications" (page 52) SFP labels The Nortel label on a typical SFP contains a Nortel serial number, a bar code, a manufacturer’s code, an interface type, and a part number. Figure 4 SFP label General SFP specifications...
This device can be used with the Ethernet Routing Switch 4526FX, 4526T, 4526T-PWR, 4550T, 4550T-PWR, and 4524GT. The following table describes the T1 SFP specifications. Nortel Ethernet Routing Switch 5500 Series Installation — SFPs and XFPs NN47200-302 01.04 Standard 5.1 27 January 2010...
Line code: Binary 8 Zero Substitution (B8ZS) or Alternate Mark Inversion (AMI). • Clock: Use Rx clock or internal clock for Tx clock (Nortel recommends internal clock for Tx clock). • Framing: D4 or Extended Super Frame (ESF), depends on the framing word required by the T1 equipment at the far end.
1000BASE-SX (LC) SFP specifications 43 ATTENTION The T1 SFP module must be configured to match the parameters of the T1 equipment at the far end. If you must change the parameters, contact Nortel Technical Support. 1000BASE-T SFP specifications The 1000BASE-T SFP provides Gigabit Ethernet connectivity using a single eight-pin RJ-45 connector.
4 dB when you test the CWDM SFP in loopback mode, or use short runs of fiber with no intermediate CWDM OADM or CWDM OMUX. Nortel Ethernet Routing Switch 5500 Series Installation — SFPs and XFPs NN47200-302 01.04 Standard 5.1 27 January 2010...
46 SFP specifications To determine the expected signal loss for an optical add drop multiplexer (OADM), an optical multiplexer (OMUX), or fiber length, see Nortel Ethernet Routing Switch 8600 Planning and Engineering — Network Design (NN46205-200). Table 20 1000BASE-XD CWDM (40 km) SFP specifications...
The following table describes the 1000BASE-XD DDI SFP. This SFP operates at 1550 nm and has a reach of up to 40 km. The part number is AA1419051-E6. Nortel Ethernet Routing Switch 5500 Series Installation — SFPs and XFPs NN47200-302 01.04 Standard 5.1 27 January 2010...
The following table describes the 1000BASE-EX DDI SFP. This SFP operates at 1550 nm and has a reach of up to 120 km. The part number of this SFP is AA1419071-E6. Nortel Ethernet Routing Switch 5500 Series Installation — SFPs and XFPs NN47200-302 01.04 Standard 5.1 27 January 2010...
Factor Pluggable (XFP) transceivers, and lists some technical specifications for the supported XFP models. ATTENTION Nortel recommends that you only use Nortel qualified XFPs. If you do choose to use other vendor XFPs, be aware that Nortel does not support the use of other XFPs. Navigation •...
Procedure job aid: XFP models XFPs are hot-swappable input/output enhancement components designed for use with Nortel products to allow 10 Gigabit Ethernet ports to link with other 10 Gigabit Ethernet ports. All Nortel XFPs use LC connectors (Lucent optical connectors) to provide precision keying and low interface losses.
Installing an XFP 57 Table 32 XFP models for the Ethernet Routing Switch 5500 Series Model number Product number Description 10GBASE-SR AA1403005-E5 850 nanometers (nm). The range is up to: • 22 m using 62.5 micrometer (µm), 160 megaHertz times km (MHz-km) MMF 33 m using 62.5 µm, 200 MHz-km MMF...
Page 58
Only trained personnel can install this product. CAUTION Risk of equipment damage Nortel recommends that you install only one 10GBASE-ZR/ZW per module due to cooling limitations on the 8683XLR and 8683XZR modules. Nortel further recommends the installation of the XFP only in port 1. You can install a 10GBASE-SR, -LR/LW, or -ER/EW in one or both of the remaining ports.
Page 59
The following figure shows a typical bail-type mechanism used on XFP transceivers. Pull the bail down to release the device. Figure 7 XFP with bail lock and extraction mechanism Nortel Ethernet Routing Switch 5500 Series Installation — SFPs and XFPs NN47200-302 01.04 Standard 5.1 27 January 2010...
For more details, see these standards documents. All Nortel XFPs meet or exceed these standards. ATTENTION Nortel recommends that you only use Nortel-qualified XFPs. If you do choose to use other vendor XFPs, be aware that Nortel does not support the use of other XFPs. Navigation •...
IEEE 802.3ae standard. The 10GBASE-SR XFP is supported by the Ethernet Routing Switch 5530 (not by the 5510 or 5520). Nortel Ethernet Routing Switch 5500 Series Installation — SFPs and XFPs NN47200-302 01.04 Standard 5.1 27 January 2010...
The stressed sensitivity values are for system level BER measurements, which include the effects of CDR circuits. Nortel recommends that you allocate at least 0.4 dB additional margin if you make component level measurements without the effect of CDR circuits.
1550 nm. The part number of this XFP is AA1403003-E5. For more information about the 10GBASE-EX XFP, including test and measurement information and more specifications, see the IEEE 802.3ae standard. Nortel Ethernet Routing Switch 5500 Series Installation — SFPs and XFPs NN47200-302 01.04 Standard 5.1 27 January 2010...
To prevent damage to the optical receiver, ensure that at least 11 dB of attenuation is present between the transmit and receive ports. Nortel Ethernet Routing Switch 5500 Series Installation — SFPs and XFPs NN47200-302 01.04 Standard 5.1 27 January 2010...
The following table lists the transmit specifications for the 10GBASE-ZR/ZW XFP. The reach is up to 80 km at a wavelength of 1550 nm. The part number of this XFP is AA1403006-E5. Nortel Ethernet Routing Switch 5500 Series Installation — SFPs and XFPs NN47200-302 01.04 Standard 5.1 27 January 2010...
Page 76
While the information in this document is believed to be accurate and reliable, except as otherwise expressly agreed to in writing NORTEL PROVIDES THIS DOCUMENT "AS IS" WITHOUT WARRANTY OR CONDITION OF ANY KIND, EITHER EXPRESS OR IMPLIED. The information and/or products described in this document are subject to change without notice.