Status Registers
Enter ATSn=v to change a register value, where n = register number and
v = decimal value; or ATSn=^v , where ^v = hexadecimal value.
Note
Not all registers can be set by the ATSn=v (or ^v) command.
Some registers are for reference only.
To change the escape character from + to the Esc key (ASCII value of
27)
Enter ATS2=27
To return the modem to the command mode press the Esc key three
times:
(pause) Esc Esc Esc (pause)
Individual Bit Command S n . # = v
Some operators use AT commands as the primary method of changing
S-register options. However, some options stored in registers do not
have an associated AT command. For these options, the individual bit
AT command can be used to change the setting of the bit controlling the
option.
To change a single bit value within a register
Enter ATSn . # = v
where n = register number # = bit position 0 through 7 v = bit value 1 or
0
Example:
S-register 27, bit 2 selects between dial-up or leased line
operation.
AT command method:
AT&L selects dial-up operation (sets S27 bit 2 to 0)