6.4

Equipment Test Setup

6.4.1 Calibration Tools and Equipment

For any RF testing use GSM Simulators as HP8922 or Rohde & Schwarz CMD55.
For Data test use a standard PC connecting the D15 to the serial port via a Motorola Evaluation
board S9002A or use the user equipment.
Line modem.
Use the local network to make the communication.

6.4.2 Set Up the Modem for Testing

Comm1
PC
Comm2

6.4.3 Test Script Command Strings

The test script commands are recommended data strings you can use to issue commands in your
test script.
NOTE:
Used any known file to transfer from comm1 to comm2 or from Comm 2 to Comm 1.
Getting Started
§
Verify D15 is On (DSC_EN LED in the EV board will by on).
§
Activate two Terminal programs one for Comm 1 and one for comm2.
§
Verify that each terminal receive response from the DCE device (send AT and verify OK
response).
§
Start your test by sending a file from Comm to comm.
d15 Modem Integration and Application Developers Guide version draft 0.53
D15 EV board
Dtype 9 pin
D15
Line Modem
Figure 38 – D15 setup for testing
All communication between the DTE (Like the PC) and the DCE (d15 modem)
occurs at 9600 bps, no parity, 8 data bits, one stop bit.
Network
Phone lines