Technical data

4 Technical data

4.1 Safety

Functional safety
DIN EN 61508 part 1 to 7
1
SDI, SS1, SS2, SOS, SLP, SLI, SCA - 2
-
1
-
SLS, SSR, SSM, SLA, SAR
EN ISO 13849-1
1
SDI, SS1, SS2, SOS, SLP, SLI, SCA - PLd / Cat. 3
-
1
-
SLS, SSR, SSM, SLA, SAR
Startup time
PSEN enc sincos
PSEN enc HTL
PFH / PFH
, "High demand" operating mode
D
PSEN enc sincos
PSEN enc HTL
Notice
MTTF
d
PSEN enc sincos
PSEN enc HTL
2
DC
avg
Internal process safety time
Overall system
Process safety angle
Through channel-internal self-diagnosis
T
, repeat test (proof test)
1
1
In accordance with EN 61800-5-2
2
The assessment occurred in accordance with Note 2 on Table 6 of EN ISO 13849-1
Operating Manual PSEN enc sincos/HTL
1005022-EN-01
Safety Integrity Level (SIL):
- 3
Performance Level:
- PLe / Cat. 3
Time between POWER-UP and safe
incremental output
 30 ms
 50 ms
-9
5,34 * 10
1/h
-9
6.57 * 10
1/h
Measuring
system
applications
with
high
demand rate
high
1558 a
622 a
medium (90 %)
Time between occurrence of an F-error and
alarm indication
 1 ms
Angle between error occurrence and alarm
indication
± 0.3510°, at 1024 periods;
± 0.0879°, at 4096 periods;
in relation to the measuring system shaft
20 years
is
used
only
in
or
continuous
Seite 16 von 38