Installation / Preparation for Commissioning

6.7.2 PSEN enc HTL

Pin
Assignment
1
A
2
/A
3
not connected
4
B
5
/B
6
not connected
7
Z
8
/Z
9
not connected
10
not connected
11
UB
12
GND
WARNING!
Short-circuits, voltage peaks, etc. can cause operating failures and
uncontrolled operating states, as well as serious personal injuries and
damage to property.
De-energize the system before carrying out wiring work or opening and closing
electrical connections!
Operating Manual PSEN enc sincos/HTL
1005022-EN-01
Description
Track A
A
Track
inverted
Track B
Track B inverted
Track Z
Track Z inverted
Supply voltage
Ground
Level
Driver
10 - 30 V
HTL
10 - 30 V
HTL
10 - 30 V
HTL
10 - 30 V
HTL
10 - 30 V
HTL
10 - 30 V
HTL
10 - 30 V
0 V
NC
Color
white
brown
yellow
gray
blue
red
gray/pink
red/blue