Page 2
State of California, USA. The State of California, County of Santa Clara shall be the exclusive venue for the resolution of any such disputes. Supermicro's total liability for all claims will not exceed the price paid for the hardware product.
Page 3
If you have any questions, please contact our support team at: support@supermicro.com This manual may be periodically updated without notice. Please check the Supermicro website for possible updates to the manual revision level. Secure Data Deletion A secure data deletion tool designed to fully erase all data from storage devices can be found on our website: https://www.supermicro.com/about/policies/disclaimer.cfm?url=/wdl/utility/...
Preface Contents Chapter 1 Introduction 1.1 Overview ..........................8 1.2 System Features ........................9 Front View ...........................9 Control Panel .........................10 Drive Carrier Indicators .....................11 Rear View ..........................12 Top View ..........................14 1.3 System Architecture ......................15 1.4 Motherboard Layout ......................16 Quick Reference Table ......................17 Motherboard Block Diagram .....................19 Chapter 2 Server Installation 2.1 Overview ..........................20...
Page 5
Preface Chapter 3 Maintenance and Component Installation 3.1 Removing Power .......................28 3.2 Accessing the System ......................29 3.3 Processor and Heatsink Installation ...................30 Installing an LGA1700 CPU .....................30 3.4 Memory ..........................35 Memory Support ........................35 General Guidelines for Optimizing Memory Performance ..........35 DIMM Installation ......................36 DIMM Removal .........................36 3.5 Motherboard Battery ......................37...
Page 6
Preface Chapter 6 Optional Components 6.1 Optional Parts List ......................67 6.2 Power Supply Modules ......................67 6.3 Storage Control Card and Cables ..................67 6.4 CacheVault .........................67 Chapter 7 Troubleshooting and Support 7.1 Information Resources .......................68 Website ..........................68 Direct Links for the SYS-111R-M System ..............68 Direct Links for General Support and Information ............68 7.2 BMC Interface ........................69 7.3 Troubleshooting Procedures .....................70...
Form Factor 1U rackmount (WxHxD) 17.2 x 1.75 x 19.98 in Notes: A Quick Reference Guide can be found on the product page of the Supermicro website. The following safety models associated with the SYS-111R-M have been certified as compliant...
Chapter 1: Introduction 1.2 System Features The following views of the system display the main features. Refer to Appendix B for additional specifications. Front View The chassis front offers access to the storage drives, a control panel, and pull-out service tag.
Chapter 1: Introduction Control Panel Information LED NIC2 LED NIC1 LED Drive LED Power LED Figure 1-2. Control Panel LED Panel Features Feature Description Information LED Alerts operator to several states, as noted in the table below. NIC1 LED Indicates network activity on LAN1 when flashing. NIC2 LED Indicates network activity on LAN2 when flashing.
Chapter 1: Introduction Drive Carrier Indicators Each drive carrier has two LED indicators: an activity indicator and a status indicator. In RAID configurations, the status indicator lights to indicate the status of the drive. In non-RAID configurations, the status indicator remains off. See the table below for details. Drive Carrier LED Indicator Color Blinking Pattern...
Chapter 1: Introduction Rear View Dedicated LAN LAN Port COM1 LAN Port Dummy Power Power Supply 1 VGA Port Supply UID LED or Reset Button USB 3.2 Gen 1 USB 2.0 Ports Ports Figure 1-3. System: Rear View System Features: Rear Feature Description Power Supply 1...
Page 13
Chapter 1: Introduction Power Supply Indicators Power Supply Condition Green LED Amber LED No AC power to the power supply Power supply critical events causing a shutdown/failure/ OCP/OVP/Fan Fail/OTP/UVP Power supply warning events where the power supply continues to operate: high temperature, over voltage, under 1 Hz Blinking voltage, etc.
Chapter 1: Introduction Top View 600 W Titanium Level One PCIe 5.0 x16 (FHHL) in slot 1 -or- One PCIe 5.0 x8 (FHHL) in slot 1 and one PCIe 5.0 x8 (LP) in slot 2 Dedicated HBA internal slot Four DIMM slots, DDR5-4400 ECC UDIMM Two M.2 slots...
Chapter 1: Introduction 1.4 Motherboard Layout Below is a layout of the X13SCH-SYS motherboard with jumper, connector and LED locations shown. See the table on the following page for descriptions. For detailed descriptions, pinout information and jumper settings, refer to Chapter 4 or the Motherboard...
Chapter 2: Server Installation Chapter 2 Server Installation 2.1 Overview This chapter provides advice and instructions for mounting your system in a server rack. If your system is not already fully integrated with processors, system memory etc., refer to Chapter 3 for details on installing those specific components.
Chapter 2: Server Installation • This product is not suitable for use with visual display workplace devices according to §2 of the German Ordinance for Work with Visual Display Units. Rack Precautions • Ensure that the leveling jacks on the bottom of the rack are extended to the floor so that the full weight of the rack rests on them.
Chapter 2: Server Installation Airflow Equipment should be mounted into a rack so that the amount of airflow required for safe operation is not compromised. Mechanical Loading Equipment should be mounted into a rack so that a hazardous condition does not arise due to uneven mechanical loading.
Chapter 2: Server Installation 2.4 Installing the Rails There are a variety of rack units on the market, which may require a slightly different assembly procedure. The following is a basic guideline for installing the system into a rack with the rack mounting hardware provided.
Chapter 2: Server Installation Inner Rails The CSE-113MFTS-0RCNBP-1P chassis includes a set of inner rails. The inner rails are pre-attached and do not interfere with normal use of the chassis if you decide not to use a server rack. Outer Rails Installing the Outer Rails to the Rack 1.
Chapter 2: Server Installation 2.5 Installing the Server into a Rack You should now have rails attached to both the chassis and the rack. The next step is to install the server into the rack. 1. Line up the rear of the chassis rails with the front of the rack rails. 2.
Chapter 2: Server Installation Installing the Server into a Telco Rack To install the SuperServer SYS-111R-M into a Telco (or “open”) type rack, use two L-shaped brackets on either side of the chassis (four total). 1. First, determine how far the server will extend out from the front of the rack. The chassis should be positioned so that the weight is balanced between front and back.
Chapter 2: Server Installation 2.6 Removing the Chassis from the Rack Caution! It is dangerous for a single person to off-load the heavy chassis from the rack without assistance. Be sure to have sufficient assistance supporting the chassis when removing it from the rack.
Chapter 3: Maintenance and Component Installation Chapter 3 Maintenance and Component Installation This chapter provides instructions on installing and replacing main system components. To prevent compatibility issues, only use components that match the specifications and/or part numbers given. Installation or replacement of most components require that power first be removed from the system.
Chapter 3: Maintenance and Component Installation 3.2 Accessing the System The CSE-113MFTS-0RCNBP-1P features a removable top cover, which allows easy access to the inside of the chassis. Removing the Top Cover 1. Power down the system as described in Section 3.1. 2.
Thermal grease is pre-applied on a new heatsink. No additional thermal grease is needed. • Refer to the Supermicro website for updates on processor support. • All graphics in this manual are for illustrative purposes only. Your components may look different.
Page 31
Chapter 3: Maintenance and Component Installation 2. Gently push down the load lever to release and lift it, then lift the load plate to open it completely. Lever lock 3. Use your thumb and your index finger to hold the CPU. Align the small triangle maker and notches on the CPU to the corresponding triangle maker and notches on the CPU load bracket.
Page 32
Chapter 3: Maintenance and Component Installation 6. Close the load plate with the CPU inside the socket. Gently push the load lever down until it locks under the Lever Lock latch. Lever lock Attention! You can only install the CPU inside the socket in one direction. Make sure that it is properly inserted into the CPU socket before closing the load plate.
Page 33
Chapter 3: Maintenance and Component Installation Installing a Heatsink A passive type heatsink is used on the X13SCH-SYS motherboard. Note: Do not apply any thermal grease to the heatsink or the CPU die; the required amount has already been applied. 1.
Page 34
Chapter 3: Maintenance and Component Installation Removing a Heatsink We do not recommend removing the heatsink. If necessary, please follow the instructions below to prevent damage to the CPU or the CPU socket. Wait for the heatsink to cool down before removing it.
Chapter 3: Maintenance and Component Installation 3.4 Memory Memory Support The X13SCH-SYS supports up to 128 GB of DDR5 ECC UDIMM memory with speeds of up to 4400 MT/s in four memory slots. Refer to the table below for the recommended DIMM population order.
Chapter 3: Maintenance and Component Installation DIMM Installation JUIDB1 COM1 USB3/4 (3.2 Gen 1) LAN2 LAN1 IPMI_LAN 1. Insert the desired number of DIMMs USB0/1 JNCSI1 JPFR2 JTPM X550 into the memory slots based on the MH17 M.2 NVME JBT1 M.2-P recommended DIMM population table.
Chapter 3: Maintenance and Component Installation 3.5 Motherboard Battery The motherboard uses non-volatile memory to retain system information when system power is removed. This memory is powered by a lithium battery residing on the motherboard. Replacing the Battery Begin by removing power from the system.
Chapter 3: Maintenance and Component Installation 3.6 Storage Drives Your server may or may not have come with storage drives installed. Up to eight 2.5" drives are supported by the chassis. The SATA drives are mounted in drive carriers to simplify their installation and removal from the chassis.
Activity LED Blue Blinking I/O activity Status LED Solid On Failure of drive Note: Enterprise level storage drives are recommended for use in Supermicro chassis and servers. For information on recommended storage drives, visit the Supermicro website at http:// www.supermicro.com/products/nfo/files/storage/SBB-HDDCompList.pdf...
Chapter 3: Maintenance and Component Installation 3.7 PCI Expansion Card Installation The system includes a pre-installed riser card (p/n RSC-SR-68G5) that positions a standard size PCIe card at a 90 degree angle, allowing it to fit inside the chassis. Figure 3-7. Expansion Card Slots in the Chassis Expansion Card Slots Item Description...
Page 41
Chapter 3: Maintenance and Component Installation Installing PCI Expansion Cards The RSC-SR-68G5 riser card has already been pre-installed into the motherboard. Perform the following steps to install an add-on card: Begin by removing power from the system as described in section 3.1. 1.
Chapter 3: Maintenance and Component Installation 3.8 System Cooling Four 4-cm fans provide the cooling for the system. The chassis provides two additional open fan housings, where additional system fans may be added for optimal cooling. It is very important that the chassis top cover is installed for the cooling air to circulate properly through the chassis and cool the components.
Chapter 3: Maintenance and Component Installation Air Shroud The air shroud is used to concentrate airflow to maximize fan efficiency. The air shroud does not require screws to set up. Installing the Air Shroud 1. Lay the chassis on a flat, stable surface and remove the chassis cover. 2.
Chapter 3: Maintenance and Component Installation 3.9 Power Supply The SuperServer SYS-111R-M comes with one 600 W high-efficiency power supply. The power supply module has an auto-switching capability. It can automatically sense and operate with a 100 V-240 V input voltage. An additional power supply can be added to make the system redundant.
Chapter 3: Maintenance and Component Installation Replacing Power Supply Modules The steps to replace the power supply modules depends on the system and the number of modules that have failed. Hot-swap is only possible on a system with two power supplies and only when one power supply has failed.
Page 46
Chapter 3: Maintenance and Component Installation Replacing One Power Supply in a Redundant System 1. Use remote management or check the power supply LEDs to determine which power supply module has failed. 2. Push the release tab (see figure on the previous page), then pull the power supply out using the handle provided.
Chapter 4: Motherboard Connections Chapter 4 Motherboard Connections This section describes the connections on the motherboard and provides pinout definitions. Note that depending on how the system is configured, not all connections are required. The LEDs on the motherboard are also described here. A motherboard layout indicating component locations may be found in Chapter 1.
Page 48
Chapter 4: Motherboard Connections 8-Pin CPU Power Connector JPW2 is an 8-pin 12 V DC power input for the CPU that must be connected to the power supply. Refer to the table below for pin definitions. 8-pin Power Pin Definitions Pin# Definition 1 - 4...
Chapter 4: Motherboard Connections 4.2 Headers and Connectors 4-pin BMC External I C Header A system Management Bus header for IPMI 2.0 is located at JIPMB1. Connect the appropriate cable here to use the IPMB I C connection on your system. JBPNI C1 is used for backplanes.
Page 50
Chapter 4: Motherboard Connections Inlet Temperature Sensor JSEN1 is the system front inlet temperature sensor. It represents the ambient air temperature entering the system. The equivalent temperature sensor retrievable by the onboard BMC is RT0. Inlet Sensor Header Pin Definitions Pin# Definition Data...
Page 51
Port 80 connection. Use this header to enhance system performance and data security. Refer to the table below for pin definitions. Go to the following link for more information on the TPM: http://www.supermicro.com/manuals/other/TPM.pdf. Trusted Platform Module/Port80 Header Pin Definitions...
JF1 contains header pins for various buttons and indicators that are normally located on a control panel at the front of the chassis. These connectors are designed specifically for use with Supermicro chassis. See the figure below for the descriptions of the front control panel buttons and LED indicators.
Page 53
Chapter 4: Motherboard Connections Power Button The Power Button connection is located on pins 1 and 2 of JF1. Momentarily contacting both pins will power on/off the system. This button can also be configured to function as a suspend button (with a setting in the BIOS). To turn off the power when the system is in suspend mode, press the button for 4 seconds or longer.
Page 54
Chapter 4: Motherboard Connections NIC1/NIC2 (LAN1/LAN2) The NIC (Network Interface Controller) LED connection for LAN port 1 is located on pins 11 and 12 of JF1. The LED connection for LAN port 2 is located on pins 9 and 10. Attach the NIC LED cables here to display network activity.
Chapter 4: Motherboard Connections 4.3 Input/Output Ports Rear I/O Ports See the figure below for the locations and descriptions of the I/O ports on the rear of the motherboard. Figure 4-2. I/O Port Locations and Definitions Rear I/O Ports Description Description COM1 USB6 (3.2 Gen 1)
Page 56
Chapter 4: Motherboard Connections LAN Ports The X13SCH-SYS motherboard has two gigabit Ethernet ports (LAN1, LAN2) on the back I/O panel. In addition to the LAN ports, a dedicated BMC LAN port is located above USB0/1. Refer to the LED Indicator section for LAN LED information. LAN Port BMC LAN Pin Definition...
Page 57
Chapter 4: Motherboard Connections Universal Serial Bus (USB) Ports There are two USB 2.0 ports (USB0/1) on the I/O back panel and two USB 2.0 headers (USB2/3 and USB4/5) on the motherboard. The motherboard also has two USB 3.2 Gen 1 ports (USB6/7) on the I/O back panel and one front access USB 3.2 header (USB9/10).
Page 58
Press the switch again to turn off the LED indicator. UID can also be triggered via BMC on the motherboard. For more information on BMC, please refer to the BMC User's Guide posted on our website: https://www.supermicro. com/manuals/other/BMC_IPMI_X13_H13.pdf Function...
Chapter 4: Motherboard Connections 4.4 Jumpers Explanation of Jumpers To modify the operation of the motherboard, jumpers can be used to choose between optional settings. Jumpers create shorts between two pins to change the function of the connector. Pin 1 is identified with a square solder pad on the printed circuit board. See the diagram below for an example of jumping pins 1 and 2.
Page 60
Chapter 4: Motherboard Connections ME Manufacturing Mode Close pins 2–3 of jumper JPME2 to bypass SPI flash security and force the system to operate in the manufacturing mode, which allows you to flash the system firmware from a host server for system setting modifications.
Chapter 4: Motherboard Connections 4.5 LED Indicators BMC Heartbeat LED LEDM1 is the BMC Heartbeat LED. When the LED is blinking green, BMC is working. Refer to the table below for the LED status. BMC Heartbeat LED LED Color Definition Blinking Green BMC Normal LAN LEDs...
BMC KVM console. 2. Go to the Supermicro web page for your motherboard and click on "Download the Latest Drivers and Utilities", select the proper driver, and copy it to a USB flash drive.
Page 63
Chapter 5: Software 4. During Windows Setup, continue to the dialog where you select the drives on which to install Windows. If the disk you want to use is not listed, click on “Load driver” link at the bottom left corner. Figure 5-2.
The Supermicro website contains drivers and utilities for your system at https://www. supermicro.com/wdl. Some of these must be installed, such as the chipset driver. After accessing the website, go into the CDR_Images (in the parent directory of the above link) and locate the ISO file for your motherboard. Download this file to a USB flash or media drive.
5.3 SuperDoctor ® The Supermicro SuperDoctor 5 is a program that functions in a command-line or web-based interface for Windows and Linux operating systems. The program monitors such system health information as CPU temperature, system voltages, system power consumption, fan speed, and provides alerts via email or Simple Network Management Protocol (SNMP).
There are several BIOS settings that are related to BMC. For general documentation and information on BMC, visit our website at: https://www.supermicro.com/en/solutions/management-software/bmc-resources BMC ADMIN User Password For security, each system is assigned a unique default BMC password for the ADMIN user.
Chapter 6: Optional Components Chapter 6 Optional Components This chapter describes optional system components and installation procedures. 6.1 Optional Parts List Optional Parts List Description Part Number Quantity Power Supply PWS-602A-1R Inlet Thermal Sensor MCP-280-00033-0N Cooling Fan FAN-0154L4 AOC-S3808L-L8IT Storage Control Card and Cable AOC-S3908L-H8iR-16DD CacheVault BTR-L3-00099-02 + MCP-240-81305-0N (For S3908)
Chapter 7: Troubleshooting and Support Chapter 7 Troubleshooting and Support 7.1 Information Resources Website A great deal of information is available on the Supermicro website, supermicro.com. Products Figure 7-1. Supermicro Website • Specifications for servers and other hardware are available by clicking on Products.
Chapter 7: Troubleshooting and Support Direct Links (continued) Supermicro Phone and Addresses 7.2 BMC Interface The system supports a Baseboard Management Controller (BMC) interface. It provides remote access, monitoring and management. There are several BIOS settings related to the BMC.
Chapter 7: Troubleshooting and Support 7.3 Troubleshooting Procedures Use the following procedures to troubleshoot your system. If you have followed all of the procedures below and still need assistance, refer to the Technical Support Procedures Returning Merchandise for Service section(s) in this chapter. Power down the system before changing any non hot-swap hardware components.
• Memory: Make sure that the memory modules are supported. Refer to the product page on our website at www.supermicro.com. Test the modules using memtest86 or a similar utility. • Storage drives: Make sure that all drives work properly. Replace if necessary.
Page 72
Also check the Control panel Overheat LED. • Adequate power supply: Make sure that the power supply provides adequate power to the system. Make sure that all power connectors are connected. Refer to the Supermicro website for the minimum power requirements. •...
In the event of a processor internal error (IERR) that crashes your system, you may want to provide information to support staff. You can download a crash dump of status information using the BMC Dashboard. The BMC manual is available at https://www.supermicro.com/ manuals/other/BMC_IPMI_X13_H13.pdf. Check Error Log 1.
Chapter 7: Troubleshooting and Support 7.5 CMOS Clear JBT1 is used to clear CMOS, which will also clear any passwords. Instead of pins, this jumper consists of contact pads to prevent accidentally clearing the contents of CMOS. To Clear CMOS 1.
7.6 Where to Get Replacement Components If you need replacement parts for your system, to ensure the highest level of professional service and technical support, purchase exclusively from our Supermicro Authorized Distributors/System Integrators/Resellers. A list can be found at: http://www.supermicro.com.
For issues related to Red Hat Enterprise Linux, since it is a subscription based OS, contact your account representative. 7.8 Feedback Supermicro values your feedback as we strive to improve our customer experience in all facets of our business. To provide feedback on our manuals, please email us at techwriterteam@...
Supermicro's Technical Support department for assistance. Only certified technicians should attempt to install or configure components. Read this appendix in its entirety before installing or configuring components in the Supermicro chassis. These warnings may also be found on our website at http://www.supermicro.com/about/...
Page 78
Appendix A: Warning Statements Warnung WICHTIGE SICHERHEITSHINWEISE Dieses Warnsymbol bedeutet Gefahr. Sie befinden sich in einer Situation, die zu Verletzungen führen kann. Machen Sie sich vor der Arbeit mit Geräten mit den Gefahren elektrischer Schaltungen und den üblichen Verfahren zur Vorbeugung vor Unfällen vertraut. Suchen Sie mit der am Ende jeder Warnung angegebenen Anweisungsnummer nach der jeweiligen Übersetzung in den übersetzten Sicherheitshinweisen, die zusammen mit diesem Gerät ausgeliefert wurden.
Page 79
Appendix A: Warning Statements . ٌ ا ك ً ف حالة و ٌ يك أى تتسبب ف اصابة جسذ ة ٌ هذا الزهز ع ٌ خطز !تحذ ز قبل أى تعول عىل أي هعذات،يك عىل علن بالوخاطز ال ا ٌجوة عي الذوائز ٍ...
Page 80
Appendix A: Warning Statements Warnung Vor dem Anschließen des Systems an die Stromquelle die Installationsanweisungen lesen. ¡Advertencia! Lea las instrucciones de instalación antes de conectar el sistema a la red de alimentación. Attention Avant de brancher le système sur la source d'alimentation, consulter les directives d'installation. .יש...
Page 81
Appendix A: Warning Statements Warnung Dieses Produkt ist darauf angewiesen, dass im Gebäude ein Kurzschluss- bzw. Überstromschutz installiert ist. Stellen Sie sicher, dass der Nennwert der Schutzvorrichtung nicht mehr als: 250 V, 20 A beträgt. ¡Advertencia! Este equipo utiliza el sistema de protección contra cortocircuitos (o sobrecorrientes) del edificio.
Page 82
Appendix A: Warning Statements Power Disconnection Warning Warning! The system must be disconnected from all sources of power and the power cord removed from the power supply module(s) before accessing the chassis interior to install or remove system components (except for hot-swap components). 電源切断の警告...
Page 83
Appendix A: Warning Statements אזהרה מפני ניתוק חשמלי !אזהרה יש לנתק את המערכת מכל מקורות החשמל ויש להסיר את כבל החשמלי מהספק .לפני גישה לחלק הפנימי של המארז לצורך התקנת או הסרת רכיבים يجب فصم اننظاو من جميع مصادر انطاقت وإ ز انت سهك انكهرباء من وحدة امداد انطاقت...
Page 84
Appendix A: Warning Statements Attention Seul le personnel autorisé et le personnel de maintenance qualifié doivent être autorisés à installer, remplacer ou entretenir cet équipement.. !אזהרה .יש לאפשר רק צוות מורשה ואנשי שירות מוסמכים להתקין, להחליף או לטפל בציוד זה .ينبغي...
Page 85
Appendix A: Warning Statements Warnung Diese Einheit ist zur Installation in Bereichen mit beschränktem Zutritt vorgesehen. Der Zutritt zu derartigen Bereichen ist nur mit einem Spezialwerkzeug, Schloss und Schlüssel oder einer sonstigen Sicherheitsvorkehrung möglich. ¡Advertencia! Esta unidad ha sido diseñada para instalación en áreas de acceso restringido. Sólo puede obtenerse acceso a una de estas áreas mediante la utilización de una herramienta especial, cerradura con llave u otro medio de seguridad.
Page 86
Appendix A: Warning Statements Battery Handling Warning! There is the danger of explosion if the battery is replaced incorrectly. Replace the battery only with the same or equivalent type recommended by the manufacturer. Dispose of used batteries according to the manufacturer's instructions 電池の取り扱い...
Page 87
Appendix A: Warning Statements هناك خطر من انفجار يف حالة اسحبذال البطارية بطريقة غري صحيحة فعليل اسحبذال البطارية فقط بنفس النىع أو ما يعادلها مام أوصث به الرشمة املصنعة جخلص من البطاريات املسحعملة وفقا لحعليامت الرشمة الصانعة 경고! 배터리가 올바르게 교체되지 않으면 폭발의 위험이 있습니다. 기존 배터리와 동일하거나 제 조사에서...
Page 88
Appendix A: Warning Statements ¡Advertencia! Puede que esta unidad tenga más de una conexión para fuentes de alimentación. Para cortar por completo el suministro de energía, deben desconectarse todas las conexiones. Attention Cette unité peut avoir plus d'une connexion d'alimentation. Pour supprimer toute tension et tout courant électrique de l'unité, toutes les connexions d'alimentation doivent être débranchées.
Page 89
Appendix A: Warning Statements Backplane Voltage Warning! Hazardous voltage or energy is present on the backplane when the system is operating. Use caution when servicing. バックプレーンの電圧 システムの稼働中は危険な電圧または電力が、 バックプレーン上にかかっています。 修理する際には注意く ださい。 警告 当系统正在进行时,背板上有很危险的电压或能量,进行维修时务必小心。 警告 當系統正在進行時,背板上有危險的電壓或能量,進行維修時務必小心。 Warnung Wenn das System in Betrieb ist, treten auf der Rückwandplatine gefährliche Spannungen oder Energien auf.
Page 90
Appendix A: Warning Statements هناك خطز مه التيار الكهزبايئ أوالطاقة املىجىدة عىل اللىحة عندما يكىن النظام يعمل كه حذ ر ا عند خدمة هذا الجهاس 경고! 시스템이 동작 중일 때 후면판 (Backplane)에는 위험한 전압이나 에너지가 발생 합니다. 서비스 작업 시 주의하십시오. Waarschuwing Een gevaarlijke spanning of energie is aanwezig op de backplane wanneer het systeem in gebruik is.
Page 91
Appendix A: Warning Statements תיאום חוקי החשמל הארצי !אזהרה .התקנת הציוד חייבת להיות תואמת לחוקי החשמל המקומיים והארציים تركيب املعدات الكهربائية يجب أن ميتثل للقىاويه املحلية والىطىية املتعلقة بالكهرباء 경고! 현 지역 및 국가의 전기 규정에 따라 장비를 설치해야 합니다. Waarschuwing Bij installatie van de apparatuur moet worden voldaan aan de lokale en nationale elektriciteitsvoorschriften.
Page 92
Appendix A: Warning Statements Attention La mise au rebut ou le recyclage de ce produit sont généralement soumis à des lois et/ou directives de respect de l'environnement. Renseignez-vous auprès de l'organisme compétent. סילוק המוצר !אזהרה .סילוק סופי של מוצר זה חייב להיות בהתאם להנחיות וחוקי המדינה التخلص...
Page 93
Appendix A: Warning Statements Warnung Gefährlich Bewegende Teile. Von den bewegenden Lüfterblätter fern halten. Die Lüfter drehen sich u. U. noch, wenn die Lüfterbaugruppe aus dem Chassis genommen wird. Halten Sie Finger, Schraubendreher und andere Gegenstände von den Öffnungen des Lüftergehäuses entfernt.
Page 94
Verbindungskabeln, Stromkabeln und/oder Adapater, die Ihre örtlichen Sicherheitsstandards einhalten. Der Gebrauch von anderen Kabeln und Adapter können Fehlfunktionen oder Feuer verursachen. Die Richtlinien untersagen das Nutzen von UL oder CAS zertifizierten Kabeln (mit UL/CSA gekennzeichnet), an Geräten oder Produkten die nicht mit Supermicro gekennzeichnet sind.
Page 96
사항을 준수하여 제공되거나 지정된 연결 혹은 구매 케이블, 전원 케이블 및 AC 어댑터를 사용하십시오. 다른 케이블이나 어댑터를 사용하면 오작동이나 화재가 발생할 수 있습니다. 전기 용품 안전법은 UL 또는 CSA 인증 케이블 (코드에 UL / CSA가 표시된 케이블)을 Supermicro 가 지정한 제품 이외의 전기 장치에 사용하는 것을 금지합니다. Stroomkabel en AC-Adapter...
Appendix B: System Specifications Appendix B System Specifications Processors Single Intel® Xeon® E-2400 or 12th Generation Pentium® (Socket V0 - LGA 1700) series processor with up to eight cores Note: Refer to the motherboard specifications pages on our website for updates to supported processors. Chipset Intel C266...
Need help?
Do you have a question about the SuperServer SYS-111R-M and is the answer not in the manual?