Manual Mode; Bin Vibrator/Cement Aeration - Rice Lake FlexWeigh 1280 Operation Manual

Hide thumbs Also See for FlexWeigh 1280:
Table of Contents

Advertisement

1280 FlexWeigh Systems Concrete Batcher

4.10 Manual Mode

Once Manual Mode is engaged, the system turns the background gray. While in Manual Mode, the operator can press the Bin
1 – 3 Vibrator, Cement 1 Air or Cement 2 Air and Dust Collector 1 or Dust Collector 2 buttons to toggle the respective
outputs on and off. All other outputs are controlled by the switches on the front panel. No other options will be available until
Manual Mode is disengaged.
• Turn the manual mode switch to the right to engage manual mode.
• Turn the manual mode switch to the left to disengage manual mode
NOTE: The system updates the actual weight as weight is dispensed (only if not running a batch). If running a batch, the
actual weight dispensed is updated upon exiting Manual Mode.
The system clears the values in each bin/admixture upon the start of the next batch.

4.11 Bin Vibrator/Cement Aeration

If the bin vibrator/cement aeration condition is set to ALWAYS, Bin X Vibrator/Cement X Air Output will be on the entire time Bin
X Feed/Cement X Feed Output is on.
If the bin vibrator/cement aeration condition is set to NO FLOW, the system will check if the flow rate is LESS THAN the Min
Flow Rate for Bin X/Cement X. If less than, the system will turn on Bin X Vibrator/Cement X Air Output for the remainder of
the time Bin X Feed/Cement X Feed Output is on.
If the bin vibrator/cement aeration condition is set to NONE, nothing happens.
26
Visit our website
Figure 4-6. Manual Input Enabled