ADF Web HD67225-A1 User Manual

ADF Web HD67225-A1 User Manual

Nmea2000/modbus tcp slave

Advertisement

Quick Links

Industrial Electronic Devices
User Manual
Revision 1.100
English
NMEA 2000 / Modbus TCP Slave
- Converter
(Order Code: HD67225-A1, HD67225-B2)
for Website information:
www.adfweb.com?Product=HD67225-A1
www.adfweb.com?Product=HD67225-B2
for Price information:
www.adfweb.com?Price=HD67225-A1
www.adfweb.com?Price=HD67225-B2
Benefits and Main Features:
Very easy to configure
Low cost
32mm Rail DIN mount
Wide supply input range
Temperature range: -40°C/+85°C (-40°F/+185°F)
User Manual
ADFweb.com Srl – IT31010 – Mareno – Treviso
User Manual NMEA2000 / Modbus TCP Slave
Document code: MN67225_ENG
Revision 1.100
For others Gateways / Bridges:
NMEA2000 to Modbus
See also the following links:
www.adfweb.com?Product=HD67222
CANopen to Modbus
See also the following links:
www.adfweb.com?Product=HD67001
www.adfweb.com?Product=HD67502
www.adfweb.com?Product=HD67004
www.adfweb.com?Product=HD67505
For others Gateways / Bridges:
For CAN bus 2.0A and/or CAN bus 2.0B to Modbus
See also the following links:
www.adfweb.com?Product=HD67011
www.adfweb.com?Product=HD67012
www.adfweb.com?Product=HD67514
www.adfweb.com?Product=HD67515
Do you have an your customer protocol?
See the following links:
www.adfweb.com?Product=HD67003
Do you need to choose a device? do you want help?
Ask it to the following link:
www.adfweb.com?Cmd=helpme
INFO:
www.adfweb.com
Phone +39.0438.30.91.31
Page 1 of 30
(Modbus RTU)
(Modbus RTU Master)
(Modbus RTU Slave)
(Modbus TCP Master)
(Modbus TCP Slave)
(Modbus RTU Slave)
(Modbus RTU Master)
(Modbus TCP Slave)
(Modbus TCP Master)

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the HD67225-A1 and is the answer not in the manual?

Questions and answers

Summary of Contents for ADF Web HD67225-A1

  • Page 1 Page 1 of 30 Industrial Electronic Devices User Manual Revision 1.100 English NMEA 2000 / Modbus TCP Slave - Converter (Order Code: HD67225-A1, HD67225-B2) For others Gateways / Bridges: for Website information: NMEA2000 to Modbus www.adfweb.com?Product=HD67225-A1 See also the following links: www.adfweb.com?Product=HD67225-B2 www.adfweb.com?Product=HD67222...
  • Page 2: Table Of Contents

    User Manual NMEA2000 / Modbus TCP Slave Document code: MN67225_ENG Revision 1.100 Page 2 of 30 Industrial Electronic Devices INDEX: UPDATED DOCUMENTATION: Dear customer, we thank you for your attention and we remind you that you need to check that the following document is: Page INDEX Updated...
  • Page 3: Security Alert

    User Manual NMEA2000 / Modbus TCP Slave Document code: MN67225_ENG Revision 1.100 Page 3 of 30 Industrial Electronic Devices SECURITY ALERT: ENERAL NFORMATION To ensure safe operation, the device must be operated according to the instructions in the manual. When using the device are required for each individual application, legal and safety regulation.
  • Page 4: Example Of Connection

    User Manual NMEA2000 / Modbus TCP Slave Document code: MN67225_ENG Revision 1.100 Page 4 of 30 Industrial Electronic Devices EXAMPLES OF CONNECTION: ADFweb.com Srl – IT31010 – Mareno – Treviso INFO: www.adfweb.com Phone +39.0438.30.91.31...
  • Page 5: Connection Scheme

    User Manual NMEA2000 / Modbus TCP Slave Document code: MN67225_ENG Revision 1.100 Page 5 of 30 Industrial Electronic Devices CONNECTION SCHEME: Figure 1a: Connection scheme for HD67225-A1 ADFweb.com Srl – IT31010 – Mareno – Treviso INFO: www.adfweb.com Phone +39.0438.30.91.31...
  • Page 6 User Manual NMEA2000 / Modbus TCP Slave Document code: MN67225_ENG Revision 1.100 Page 6 of 30 Industrial Electronic Devices Figure 1b: Connection scheme for HD67225-B2 ADFweb.com Srl – IT31010 – Mareno – Treviso INFO: www.adfweb.com Phone +39.0438.30.91.31...
  • Page 7: Characteristics

    User Manual NMEA2000 / Modbus TCP Slave Document code: MN67225_ENG Revision 1.100 Page 7 of 30 Industrial Electronic Devices CHARACTERISTICS: The “NMEA 2000 / Modbus TCP Slave – Converter” allows the following characteristics: two-directional information between networks NMEA 2000 and Modbus; electrical isolation between two Buses;...
  • Page 8: Power Supply

    The devices can be powered at 8…24V AC and 12…35V DC. For more details see the two tables below. Vmin Vmax Vmin Vmax Consumption at 24V DC: Device Consumption [W/VA] HD67225-A1 HD67225-B2 Caution: Not reverse the polarity power HD67225-A1 HD67225-B2 ADFweb.com Srl – IT31010 – Mareno – Treviso INFO: www.adfweb.com...
  • Page 9: Function Modes

    User Manual NMEA2000 / Modbus TCP Slave Document code: MN67225_ENG Revision 1.100 Page 9 of 30 Industrial Electronic Devices FUNCTION MODES: The device has got two function modes depending on the position of the ‘Dip2 of Dip-Switch A’: The first, with ‘Dip2 of Dip-Switch A’ at “OFF” position, is used for the normal working of the device. The second, with ‘Dip2 of Dip-Switch A’...
  • Page 10: Leds

    User Manual NMEA2000 / Modbus TCP Slave Document code: MN67225_ENG Revision 1.100 Page 10 of 30 Industrial Electronic Devices LEDS: The devices has got four (five for HD67225-B2) LEDs that are used to give information of the functioning status. The various meanings of the LEDs are described in the table below. Normal Mode Boot Mode Blinks quickly: Boot state...
  • Page 11: Ethernet

    ETHERNET: The Ethernet connection must be made using Connector5 of HD67225-A1/HD67225-B2 with at least a Category 5E cable. The maximum length of the cable should not exceed 100m. The cable has to conform to the T568 norms relative to connections in cat.5 up to 100 Mbps. To connect the device to a Hub/Switch the use of a straight cable is recommended.
  • Page 12: Nmea 2000

    User Manual NMEA2000 / Modbus TCP Slave Document code: MN67225_ENG Revision 1.100 Page 12 of 30 Industrial Electronic Devices NMEA 2000: For terminating the NMEA 2000 line with a 120Ω resistor it is necessary that the Dip1 of ‘Dip-Switch C’ is at ON position. Cable characteristics: DC parameter: Impedance...
  • Page 13: Use Of Compositor Sw67225

    User Manual NMEA2000 / Modbus TCP Slave Document code: MN67225_ENG Revision 1.100 Page 13 of 30 Industrial Electronic Devices USE OF COMPOSITOR SW67225: To configure the Converter, use the available software that runs with Windows called SW67225. It is downloadable on the site www.adfweb.com and its operation is described in this document.
  • Page 14: New Project / Open Project

    User Manual NMEA2000 / Modbus TCP Slave Document code: MN67225_ENG Revision 1.100 Page 14 of 30 Industrial Electronic Devices NEW CONFIGURATION / OPEN CONFIGURATION: “New Configuration” button creates the folder which contains the entire device’s configuration. A device’s configuration can also be imported or exported: To clone the configurations of a programmable “NMEA 2000 / Modbus TCP Slave - Converter”...
  • Page 15: Software Options

    User Manual NMEA2000 / Modbus TCP Slave Document code: MN67225_ENG Revision 1.100 Page 15 of 30 Industrial Electronic Devices SOFTWARE OPTIONS: By pressing the “Settings” ( ) button there is the possibility to change the language of the software and check the updatings for the compositor.
  • Page 16: Set Communication

    User Manual NMEA2000 / Modbus TCP Slave Document code: MN67225_ENG Revision 1.100 Page 16 of 30 Industrial Electronic Devices SET COMMUNICATION: This section defines the fundamental communication parameters of two Buses, NMEA 2000 and Modbus TCP. By pressing the “Set Communication”...
  • Page 17 User Manual NMEA2000 / Modbus TCP Slave Document code: MN67225_ENG Revision 1.100 Page 17 of 30 Industrial Electronic Devices If the field “Filter FECA (ms)” is checked when the FECA PGN arrives the gateway puts the values in Standby. If the time, expressed in milliseconds and written at the right side of “Filter FECA”, is elapsed and there aren’t arrived the frames of Transport Protocol the gateway put the data of FECA into Modbus Registers.
  • Page 18: Receive Nmea 2000

    User Manual NMEA2000 / Modbus TCP Slave Document code: MN67225_ENG Revision 1.100 Page 18 of 30 Industrial Electronic Devices RECEIVE NMEA 2000: By pressing the “Receive NMEA 2000” button from the main window for SW67225 (Fig. 2) the window “Receive CAN Frames Definition” appears (Fig.
  • Page 19 User Manual NMEA2000 / Modbus TCP Slave Document code: MN67225_ENG Revision 1.100 Page 19 of 30 Industrial Electronic Devices If “Device from May 2014 (with Dip-Switches)” is set in the section “Set Communication”, the window appears like below: Figure 4b: “Receive NMEA 2000 Frames” window In the field “PGN”...
  • Page 20: Define Receive Nmea 2000

    User Manual NMEA2000 / Modbus TCP Slave Document code: MN67225_ENG Revision 1.100 Page 20 of 30 Industrial Electronic Devices DEFINE NMEA 2000: By pressing the “Define COB” button near “Receive NMEA 2000” from the main window for SW67225 (Fig. 2) the window “Define Modbus Registers for Receive NMEA 2000 Frames”...

This manual is also suitable for:

Hd67225-b2

Table of Contents